Your browser doesn't support javascript.
loading
Electrochemical immuno determination of connective tissue growth factor levels on nitrogen-doped graphene.
Ma, Jing; Chen, Junhui; Li, YuanYuan; Zhang-Peng, Xinru; Wei, Hong; Li, Wen; Hu, Fangdi; Zhang, Yan.
Afiliação
  • Ma J; School of Pharmacy@the State Key Laboratory of Applied Organic Chemistry (SKLAOC), Lanzhou University, Lanzhou, 730000, China.
  • Chen J; Department of Pediatrics, Gansu Province People's Hospital, 204 Donggang West Road, Lanzhou, 730000, People's Republic of China.
  • Li Y; School of Pharmacy@the State Key Laboratory of Applied Organic Chemistry (SKLAOC), Lanzhou University, Lanzhou, 730000, China.
  • Zhang-Peng X; School of Pharmacy@the State Key Laboratory of Applied Organic Chemistry (SKLAOC), Lanzhou University, Lanzhou, 730000, China.
  • Wei H; School of Pharmacy@the State Key Laboratory of Applied Organic Chemistry (SKLAOC), Lanzhou University, Lanzhou, 730000, China.
  • Li W; School of Pharmacy@the State Key Laboratory of Applied Organic Chemistry (SKLAOC), Lanzhou University, Lanzhou, 730000, China.
  • Hu F; School of Pharmacy@the State Key Laboratory of Applied Organic Chemistry (SKLAOC), Lanzhou University, Lanzhou, 730000, China. hufd@lzu.edu.cn.
  • Zhang Y; National Engineering Research Center for Gelatin-Based Traditional Chinese Medicine, Dong-E-E-Jiao Co., Ltd, Liaocheng, China. zhangyan3261967@126.com.
Mikrochim Acta ; 189(5): 187, 2022 04 09.
Article em En | MEDLINE | ID: mdl-35397015
Connective tissue growth factor (CTGF) is a disease marker of rheumatoid arthritis (RA), and its rapid and sensitive detection is essential for the diagnosis of RA. In this work, a three-dimensional pore structure of alkali-activated nitrogen-doped graphene (aN-G) was used as an electrode modification material, and a label-free electrochemical immunosensor for the sensitive detection of CTGF was successfully constructed by the formation of an amide bond between amino groups in protein and carboxyl groups on the carbon surface. Under optimized conditions, the sensor achieved accurate detection of CTGF in the wide range of 0.0625 ~ 2000 pg mL-1. It had good accuracy (95.0 ~ 100.1%), repeatability (1.2 ~ 2.2%), stability, selectivity, and a low limit of detection (0.0424 pg mL-1, S/N = 3). The sensor was used in serum samples of patients with RA, and CTGF was also successfully detected. Based on this, the electrochemical sensor is expected to become an effective method for RA diagnosis and treatment effect evaluation.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artrite Reumatoide / Técnicas Biossensoriais / Fator de Crescimento do Tecido Conjuntivo / Grafite Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artrite Reumatoide / Técnicas Biossensoriais / Fator de Crescimento do Tecido Conjuntivo / Grafite Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article