Your browser doesn't support javascript.
loading
Improvement of diffusion weighted MRI by practical B0 homogenization for head & neck cancer patients undergoing radiation therapy.
Bielak, Lars; Henrik Nicolay, Nils; Ludwig, Ute; Lottner, Thomas; Rühle, Alexander; Grosu, Anca-Ligia; Bock, Michael.
Afiliação
  • Bielak L; Dept. of Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; German Cancer Consortium (DKTK), Partner Site Freiburg, Freiburg, Germany. Electronic address: lars.bielak@uniklinik-freiburg.de.
  • Henrik Nicolay N; Dept. of Radiation Oncology, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; German Cancer Consortium (DKTK), Partner Site Freiburg, Freiburg, Germany.
  • Ludwig U; Dept. of Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Lottner T; Dept. of Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Rühle A; Dept. of Radiation Oncology, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany.
  • Grosu AL; Dept. of Radiation Oncology, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; German Cancer Consortium (DKTK), Partner Site Freiburg, Freiburg, Germany.
  • Bock M; Dept. of Radiology, Medical Physics, Medical Center University of Freiburg, Faculty of Medicine, University of Freiburg, Freiburg, Germany; German Cancer Consortium (DKTK), Partner Site Freiburg, Freiburg, Germany.
Phys Med ; 97: 59-65, 2022 May.
Article em En | MEDLINE | ID: mdl-35413606
ABSTRACT

BACKGROUND:

MRI is a frequently used tool in radiation therapy planning. For MR-based tumor segmentation, diffusion weighted imaging plays a major role, which can fail due to excessive image artifacts for head and neck cancer imaging. Here, an easy-to-use setup is presented for imaging of head and neck cancer patients in a radiotherapy thermoplastic fixation mask.

METHODS:

In a prospective head and neck cancer study, MRI data of 29 patients has been acquired at 3 different time points during radiation treatment. The data was analyzed with respect to Nyquist ghosting artifacts in the diffusion images in conventional single shot and readout segmented EPI sequences. For 9 patients, an improved setup with water bags for B0 homogenization was used, and the impact on artifact frequency was analyzed. Additionally, volunteer measurements with B0 fieldmaps are presented.

RESULTS:

The placement of water bags to the sides of the head during MRI measurements significantly reduces artefacts in diffusion MRI. The number of artifact-free images in readout segmented EPI increased from 74% to 95% of the cases. Volunteer measurements showed a significant increase in B0 homogeneity across slices (head foot direction) as well as within each slice.

CONCLUSIONS:

The placement of water bags for B0 homogenization is easy to implement, cost-efficient and does not impact patient comfort. Therefore, if very sophisticated soft- or hardware solutions are not present at a given site, or cannot be implemented due to restrictions from the thermoplastic mask, this is an excellent alternative to reduce artifacts in diffusion weighted imaging.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imagem Ecoplanar / Neoplasias de Cabeça e Pescoço Tipo de estudo: Clinical_trials / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imagem Ecoplanar / Neoplasias de Cabeça e Pescoço Tipo de estudo: Clinical_trials / Observational_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article