Your browser doesn't support javascript.
loading
Biomedical point-of-care microanalyzer for potentiometric determination of ammonium ion in plasma and whole blood.
Calvo-López, Antonio; Rebollo-Calderon, Beatriz; Ormazábal, Aida; Artuch, Rafael; Rosell-Ferrer, Javier; Alonso-Chamarro, Julián; Puyol, Mar.
Afiliação
  • Calvo-López A; Group of Sensors and Biosensors, Department of Chemistry, Autonomous University of Barcelona, Edifici Cn, 08193, Bellaterra, Barcelona, Spain.
  • Rebollo-Calderon B; Group of Sensors and Biosensors, Department of Chemistry, Autonomous University of Barcelona, Edifici Cn, 08193, Bellaterra, Barcelona, Spain.
  • Ormazábal A; Clinical Biochemistry Department. Institut de Recerca Sant Joan de Déu, CERCA and CIBERER-ISCIII, Passeig de Sant Joan de Déu, 2, 08950, Esplugues de Llobregat, Barcelona, Spain.
  • Artuch R; Clinical Biochemistry Department. Institut de Recerca Sant Joan de Déu, CERCA and CIBERER-ISCIII, Passeig de Sant Joan de Déu, 2, 08950, Esplugues de Llobregat, Barcelona, Spain.
  • Rosell-Ferrer J; Research Centre for Biomedical Engineering (CREB), Universitat Politècnica de Catalunya (UPC), Campus Diagonal Sud, Edifici H., Av. Diagonal 647, Barcelona, Spain.
  • Alonso-Chamarro J; Group of Sensors and Biosensors, Department of Chemistry, Autonomous University of Barcelona, Edifici Cn, 08193, Bellaterra, Barcelona, Spain.
  • Puyol M; Group of Sensors and Biosensors, Department of Chemistry, Autonomous University of Barcelona, Edifici Cn, 08193, Bellaterra, Barcelona, Spain. Electronic address: mariadelmar.puyol@uab.cat.
Anal Chim Acta ; 1205: 339782, 2022 May 01.
Article em En | MEDLINE | ID: mdl-35414388
Some inborn errors of metabolism and other diseases can result in increasing blood ammonium (hyperammonemia episodes), which can cause serious neurological complications in patients or even death. Early diagnosis, follow up and treatment are essential to minimize irreversible damages in brain. Currently, adequate analytical instrumentation for the necessary ammonium bedside determination is not available in all health centers but only in clinical laboratories of reference hospitals. We therefore have developed a low cost and portable potentiometric Point-of-Care microanalyzer (POC) to address this problem. It consists of a cyclic olefin copolymer-based microanalyzer, the size of a credit card and working in continuous flow, which integrates microfluidics, a gas-diffusion module and a potentiometric detection system. The analytical features achieved are a linear range from 30 to 1000 µmol L-1 NH4+, a detection limit of 18 µmol L-1 NH4+ and a required sample volume of 100 µL, which comply with the medical requirements. Plasma and blood samples are analyzed with no significant differences observed between ammonium concentrations obtained with both the proposed microanalyzer and the reference method. This demonstrates the value of the developed POC for bedside clinical applications.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cicloparafinas / Compostos de Amônio Tipo de estudo: Screening_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cicloparafinas / Compostos de Amônio Tipo de estudo: Screening_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article