Your browser doesn't support javascript.
loading
Closed intravenous systems for central vascular access: A difference maker for CLABSI rates in neonates?
van Rens, Matheus F P T; Hugill, Kevin; Francia, Airene L V; Mahmah, Mohamad Adnan; Al Shadad, Afaf Boulous J; Chiuco, Imelda Caseres; Garcia, Krisha L P.
Afiliação
  • van Rens MFPT; Director of Nursing and Neonatal Vascular Access Lead, Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar.
  • Hugill K; Director of Nursing Education, Hamad Medical Corporation, Doha, Qatar.
  • Francia ALV; Vascular Access and Neonatal Transport Team Coordinator, Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar.
  • Mahmah MA; Senior Consultant Critical Care, QI lead, Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar.
  • Al Shadad ABJ; Senior Consultant Critical Care, Infection Control Lead, Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar.
  • Chiuco IC; Infection Control Practitioner, Women's Wellness and Research Center, Doha, Qatar.
  • Garcia KLP; Nurse Educator, Neonatal Intensive Care Unit, Women's Wellness and Research Center, Hamad Medical Corporation, Doha, Qatar.
J Vasc Access ; 24(6): 1390-1397, 2023 Nov.
Article em En | MEDLINE | ID: mdl-35435032
ABSTRACT

BACKGROUND:

Infants in neonatal units are susceptible to numerous potential iatrogenic risks. One key concern is central line-associated blood stream infection (CLABSI). To ensure patient safety and reduce the incidence of CLABSI toward zero, numerous evidence-based clinical interventions and product innovations have been implemented. Nevertheless, sustaining zero CLABSI for sustained periods remains challenging.

AIM:

The purpose of this study was to evaluate the impact on CLABSI rates of introducing a preassembled closed intravenous (IV) administration set in a neonatal intensive care unit (NICU).

METHODS:

This was a retrospective observational analysis of routinely collected anonymized IV therapy infection data in a NICU. The study period was from January 2019 through June 2020.

RESULTS:

Nine-hundred eighty five patients with a Epicutaneo-Caval Catheter (ECC) were included (456 legacy IV set, 529 closed IV set). Patient demographics were comparable between the two groups. ECC dwell time was the only IV characteristic associated (p = 0.04) with CLABSI. Mann-Whitney U-test demonstrated significant differences between the two sets for CLABSI complication events (p = 0.031). Prior to using the closed IV administration sets (January 2019-September 2019) the mean monthly CLABSI rate was 2.87 (/1000 device days). This figure declined to 0.22 (/1000 device days) afterwards (October 2019-June 2020). Zero CLABSIs were observed during January to June 2020.

CONCLUSIONS:

Utilization of a pre-assembled closed IV administration set was associated with a reduction in CLABSI rates. The study results suggest that using a pre-assembled closed IV set concurrently with evidence-based central line infection control interventions can help attain extended periods of zero CLABSI.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cateterismo Venoso Central / Infecções Relacionadas a Cateter / Cateteres Venosos Centrais Limite: Humans / Infant / Newborn Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cateterismo Venoso Central / Infecções Relacionadas a Cateter / Cateteres Venosos Centrais Limite: Humans / Infant / Newborn Idioma: En Ano de publicação: 2023 Tipo de documento: Article