Your browser doesn't support javascript.
loading
A cleanup method of serum extracts with molecular sieves as SPE sorbents for the analysis of polybrominated diphenyl ethers.
Liu, Hongyuan; Jin, Jing; Xue, Huifu; Guo, Cuicui; Ren, Feng; He, Xiaolin; Chen, Jiping; Hu, Chun.
Afiliação
  • Liu H; School of pharmacy, Shenyang Pharmaceutical University, Shenyang, P. R. China.
  • Jin J; CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, Liaoning, P. R. China.
  • Xue H; CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, Liaoning, P. R. China.
  • Guo C; SYN Energy Technology Co., Ltd., Dalian, P. R. China.
  • Ren F; CAS Key Laboratory of Separation Science for Analytical Chemistry, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian, Liaoning, P. R. China.
  • He X; University of Chinese Academy of Sciences, Beijing, P. R. China.
  • Chen J; The Second Hospital of Dalian Medical University, Dalian, P. R. China.
  • Hu C; The Second Hospital of Dalian Medical University, Dalian, P. R. China.
J Sep Sci ; 45(13): 2334-2343, 2022 Jul.
Article em En | MEDLINE | ID: mdl-35472733
ABSTRACT
Based on the size- and shape-selective sorption, 13X molecular sieves were developed as solid-phase extraction adsorbents to cleanup serum extract for the determination of polybrominated diphenyl ethers. The important parameters affecting the cleanup efficiency were investigated including the amount of sorbents, the type, and volume of solvents. Under the optimized conditions, the capacity for removing impurities was evaluated via gel permeation chromatography and gas chromatography with mass spectrometry. The results demonstrated that up to 99% of lipids in corn oil (13 mg) can be removed after cleanup, and endogenous compounds in serum can also be effectively eliminated. The cleanup efficiency is not only superior to hydrophile-lipophile balance column, but also close to acid silica gel and multifunction impurity sorbents. Generally, the developed cleanup method exhibited higher recovery for polybrominated diphenyl ethers with more than four bromines, especially for nona- and deca-brominated diphenyl ethers (99.1-117.8%). The cleanup method can be coupled with gas chromatography and tandem mass spectrometry for polybrominated diphenyl ethers analysis in human serum. The method detection limits were 0.01-0.27 ng/mL and average recovery was 50.9-113.3%, except 2,3',4',6-tetrabrominated, 2,3',4,4',6-pentabrominated, and 2,3,3',4,4',5',6-heptabrominated diphenyl ethers. 2,2',4,5'-Tetrabrominated diphenyl ethers had the highest detection frequency (95%) in human serum, whereas decabrominated diphenyl ethers had the maximum mean concentration (0.50 ng/mL).
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Extração em Fase Sólida / Éteres Difenil Halogenados Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Extração em Fase Sólida / Éteres Difenil Halogenados Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article