Your browser doesn't support javascript.
loading
Ultrasensitive fluorescence detection of microRNA through DNA-induced assembly of carbon dots on gold nanoparticles with no signal amplification strategy.
He, Mengyuan; Shang, Ning; Zheng, Bo; Yue, Gege; Han, Xi; Hu, Xuebo.
Afiliação
  • He M; College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, 464000, China. myhe@xynu.edu.cn.
  • Shang N; College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, 464000, China.
  • Zheng B; College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, 464000, China.
  • Yue G; College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, 464000, China.
  • Han X; College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, 464000, China.
  • Hu X; College of Chemistry and Chemical Engineering, Xinyang Normal University, Xinyang, 464000, China.
Mikrochim Acta ; 189(6): 217, 2022 05 10.
Article em En | MEDLINE | ID: mdl-35538261
ABSTRACT
An ultrasensitive fluorescence assay strategy on the basis of carbon dots (CDs) and cDNA-modified gold nanoparticles (AuNP-cDNA) was developed for the determination of microRNA-21 (miRNA-21) via internal filtering effect (IFE). Positively charged CDs (PEI-CDs), the fluorophores in IFE, were synthesized via a hydrothermal method using polyethyleneimine (PEI) as surface ligand. The maximum emission wavelength is located at 500 nm under the excitation of 410 nm. AuNPs, the absorbers, were modified with single-stranded DNA (cDNA), which is completely complementary to miRNA-21. The fluorescence of PEI-CDs is quenched due to the assembly of PEI-CDs and AuNPs-cDNA. In the presence of miRNA-21, the hybridization between miRNA-21 and cDNA causes the release of PEI-CDs and the recovery of fluorescence intensity.The fluorescence recovery degree is linearly correlated with the logarithm of miRNA-21 concentration in the range of 1-1000 fM. This method can be applied to determine miRNA-21 in real serum samples, and the detection results are in well agreement with those of qRT-PCR. The determination of miRNA-21 spiked into diluted human serum samples displays satisfactory recovery within the range 88.44-112.7%, which confirmed the reliability for miRNAs detection in real samples.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: MicroRNAs / Pontos Quânticos / Nanopartículas Metálicas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: MicroRNAs / Pontos Quânticos / Nanopartículas Metálicas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article