Influence of insole material density in the stability of patients with prosthetic unilateral transtibial amputation.
Sarroca, Nuria; Luesma, María José; Valero, José; Del Caso, María Pilar; Alonso, Cristina; Calleja, Jorge; Lorenzo, Tania; Bayod, Javier; Lahoz, Manuel.
Afiliação
  • Sarroca N; Private Practice, Madre Vedruna 14 bajo derecho, 50008, Zaragoza, Spain.
  • Luesma MJ; Department of Human Anatomy and Histology, University of Zaragoza, Calle Domingo Miral s/n, 50009, Zaragoza, Spain. mjluesma@unizar.es.
  • Valero J; Private Practice, Coso 55, 50001, Zaragoza, Spain.
  • Del Caso MP; Private Practice, Baltasar Gracián 6, 50005, Zaragoza, Spain.
  • Alonso C; Daroca Health Centre (Calatayud Sector), Luchente s/n, 50360, Zaragoza, Daroca, Spain.
  • Calleja J; Department of Hospital Medicine, San Carlos Clinical Hospital, Prof Martín Lagos S/N, 28040, Madrid, Spain.
  • Lorenzo T; Private Practice, Madre Vedruna 14 bajo derecho, 50008, Zaragoza, Spain.
  • Bayod J; Department of Mechanical Engineering, University of Zaragoza, 50009, Zaragoza, Spain.
  • Lahoz M; Department of Human Anatomy and Histology, University of Zaragoza, Calle Domingo Miral s/n, 50009, Zaragoza, Spain.
Sci Rep ; 12(1): 7854, 2022 05 12.
Article em En | MEDLINE | ID: mdl-35552421
ABSTRACT
People with lower limb amputation present greater displacements of their centre of gravity in a static situation than able-bodied individuals, as they depend on visual information to a greater extent, which implies an altered stability pattern. The efficacy of different hardness of plantar support to help maintain stability has not yet been determined. The aim of the present study is to assess stability in people with unilateral transtibial amputation with prosthesis in a static situation with insoles of different degrees of hardness and visual conditions with respect to the able-bodied population. For this purpose, 25 patients with amputation and 25 able-bodied individuals were included in both groups, postural stability was assessed by stabilometry. This assessment was carried out under normal conditions (on the floor of the dynamometric platform with eyes open), and under altered conditions (with the interposition of different materials such as plantar support rigid and soft insoles and, eyes shut). Three variables were considered to assess stability length of movement of the barycenter (mm), lateral velocity (mm/sg) and anterior velocity (mm/sg). All of them were analysed with the patient in static on the dynamometric platform. The results showed statistically significant differences between the two groups, (amputees and controls) with less stability in the amputee group (p < 0.05) when analysing the variables of length of movement of the barycenter, lateral velocity and anterior velocity. Amputee patients with open eyes exhibited greater stability than those with closed eyes. The hard insoles improved the stability data in amputees (length of movement of the barycenter and anterior velocity) with respect to the barefoot condition, and the soft insoles showed less stability than the patients with hard insoles, or than the barefoot patients. From the results obtained in this study, we can conclude that the PP-DWST 4 mm rigid insoles improve static stability in people with amputation. However, soft insoles impair stability and are therefore discouraged.