Your browser doesn't support javascript.
loading
Evaluation of the left ventricular systolic function and myocardial deformation by real-time three-dimensional (four-dimensional) and speckle-tracking echocardiography in children with type 1 diabetes mellitus.
Eroglu, Ayse G; Yüksel, Esra K; Karagözlü, Fatih; Acar, Hazal C; Gökalp, Selman; Evliyaoglu, Olcay.
Afiliação
  • Eroglu AG; Division of Pediatric Cardiology, Department of Pediatrics, Cerrahpasa Faculty of Medicine, Istanbul University-Cerrahpasa, Istanbul, Turkey.
  • Yüksel EK; Department of Pediatrics, Cerrahpasa Faculty of Medicine, Istanbul University-Cerrahpasa, Istanbul, Turkey.
  • Karagözlü F; Division of Pediatric Cardiology, Department of Pediatrics, Cerrahpasa Faculty of Medicine, Istanbul University-Cerrahpasa, Istanbul, Turkey.
  • Acar HC; Department of Public Health, Cerrahpasa Faculty of Medicine, Istanbul University-Cerrahpasa, Istanbul, Turkey.
  • Gökalp S; Division of Pediatric Cardiology, Department of Pediatrics, Cerrahpasa Faculty of Medicine, Istanbul University-Cerrahpasa, Istanbul, Turkey.
  • Evliyaoglu O; Division of Pediatric Endocrinology, Department of Pediatrics, Cerrahpasa Faculty of Medicine, Istanbul University-Cerrahpasa, Istanbul, Turkey.
Cardiol Young ; 33(4): 603-607, 2023 Apr.
Article em En | MEDLINE | ID: mdl-35575299
ABSTRACT

AIM:

This study aimed to evaluate the role of real-time three-dimensional (known as four-dimensional) echocardiography and three-dimensional speckle-tracking echocardiography for the early detection of left ventricular systolic dysfunction in asymptomatic children with type 1 diabetes mellitus. MATERIALS AND

METHOD:

This cross-sectional study included 38 patients (mean age 15.4 ± 2.9, 42.1% male) and 38 age, gender, and body measurements matched healthy children. Each patient underwent an interview about medical history, a detailed clinical examination, blood laboratory tests, conventional echocardiography, and tissue Doppler imaging. Left ventricular ejection fraction; global longitudinal, circumferential, radial strain; twist; and torsion were measured by real-time three-dimensional and speckle-tracking echocardiography.

RESULTS:

Conventional echocardiography and tissue Doppler imaging showed normal left ventricular systolic function in the patients. Although left ventricular ejection fraction (61.6 ± 1.4%, 61.8 ± 1.1%, p = 0.386), global longitudinal [-26.6 (-27.7 to -26.1)%, -26.2 (-27.7 to -24.9)%, p = 0.224], and radial strain [44.4 (42.4-45.9)%, 43.9 (41-46.1)%, p = 0.513] were similar to the controls, circumferential strain (-27.3 ± 1.3%, -28.0 ± 1.6%, p = 0.048) and twist (9.5 ± 2.3°, 11.4 ± 3.0°, p = 0.003) were decreased in the patients compared with controls.

CONCLUSION:

We found that even in children with asymptomatic type 1 diabetes mellitus with normal left ventricular ejection fraction, circumferential function was impaired and rotation pattern was changed. This novel echocardiographic method might be an important tool for detecting left ventricular systolic dysfunction in type 1 diabetes mellitus children before it becomes overt on conventional echocardiography and tissue Doppler imaging.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Disfunção Ventricular Esquerda / Ecocardiografia Tridimensional / Diabetes Mellitus Tipo 1 Tipo de estudo: Observational_studies / Screening_studies Limite: Child / Female / Humans / Male Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Disfunção Ventricular Esquerda / Ecocardiografia Tridimensional / Diabetes Mellitus Tipo 1 Tipo de estudo: Observational_studies / Screening_studies Limite: Child / Female / Humans / Male Idioma: En Ano de publicação: 2023 Tipo de documento: Article