Your browser doesn't support javascript.
loading
Characterizing Visual Fields in RPGR Related Retinitis Pigmentosa Using Octopus Static-Automated Perimetry.
Buckley, Thomas M W; Josan, Amandeep Singh; Taylor, Laura J; Jolly, Jasleen K; Cehajic-Kapetanovic, Jasmina; MacLaren, Robert E.
Afiliação
  • Buckley TMW; Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
  • Josan AS; Nuffield Laboratory of Ophthalmology, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford Biomedical Research Centre, Oxford, UK.
  • Taylor LJ; Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
  • Jolly JK; Nuffield Laboratory of Ophthalmology, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford Biomedical Research Centre, Oxford, UK.
  • Cehajic-Kapetanovic J; Oxford Eye Hospital, Oxford University Hospitals NHS Foundation Trust, Oxford, UK.
  • MacLaren RE; Nuffield Laboratory of Ophthalmology, Nuffield Department of Clinical Neurosciences, University of Oxford, Oxford Biomedical Research Centre, Oxford, UK.
Transl Vis Sci Technol ; 11(5): 15, 2022 05 02.
Article em En | MEDLINE | ID: mdl-35576214
ABSTRACT

Purpose:

Peripheral visual fields have not been as well defined by static automated perimetry as kinetic perimetry in RPGR-related retinitis pigmentosa. This study explores the pattern and sensitivities of peripheral visual fields, which may provide an important end point when assessing interventional clinical trials.

Methods:

A retrospective observational cross-sectional study of 10 genetically confirmed RPGR subjects was performed. Visual fields were obtained using the Octopus 900 perimeter. Interocular symmetry and repeatability were quantified. Visual fields were subdivided into central and peripheral subfields for analysis.

Results:

Mean patient age was 32 years old (20 to 49 years old). Average mean sensitivity was 7 dB (SD = 3.67 dB) and 6.8 dB (SD = 3.4 dB) for the right and left eyes, respectively, demonstrating interocular symmetry. Coefficient of repeatability for overall mean sensitivity <2 dB. Nine out of 10 subjects had a preserved inferotemporal subfield, whose mean sensitivity was highly correlated to the central field (r2 = 0.78, P = 0.002 and r2 = 0.72, P = 0.002 for the right and left eyes, respectively). Within the central field, sensitivities were greater in the temporal than the nasal half (t-test, P = 0.01 and P = 0.03 for the right and left eyes, respectively).

Conclusions:

Octopus static-automated perimeter demonstrates good repeatability. Interocular symmetry permits use of the noninterventional eye as an internal control. In this cohort, the inferotemporal and central visual fields are preserved into later disease stages likely mapping to populations of surviving cones. Translational Relevance A consistently preserved inferotemporal island of vision highly correlated to that of the central visual field may have significance as a possible future therapeutic site.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Retinose Pigmentar / Testes de Campo Visual Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adult / Animals / Humans / Middle aged Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Retinose Pigmentar / Testes de Campo Visual Tipo de estudo: Diagnostic_studies / Observational_studies / Prevalence_studies / Risk_factors_studies Limite: Adult / Animals / Humans / Middle aged Idioma: En Ano de publicação: 2022 Tipo de documento: Article