Your browser doesn't support javascript.
loading
Effect of Argon Plasma Surface Treatment on Repair of Resin Composite Aged Two Years.
Negreiros, W M; Ayres, Apa; Willers, A E; Hirata, R; Giannini, M.
Afiliação
  • Negreiros WM; William Matthew Negreiros, DDs, MSc, Dental Materials Division, Department of Restorative Dentistry, University of Campinas, Piracicaba Dental School, Piracicaba, SP, Brazil.
  • Ayres A; Ana Paula Almeida Ayres, DDs, MSc, PhD, associate professor, Department of Clinical Restorative Dentistry, Uberaba University, Uberaba, MG, Brazil.
  • Willers AE; Amanda Endres Willers, DDs, MSc, PhD student, Operative Dentistry Division, Department of Restorative Dentistry, University of Campinas, Piracicaba Dental School, Piracicaba, SP, Brazil.
  • Hirata R; Ronaldo Hirata, DDs, MSc, PhD, assistant professor, Department of Biomaterials and Biomimetics, New York University College of Dentistry, New York, NY, USA.
  • Giannini M; *Marcelo Giannini, DDs, MSc, PhD, associate professor, Operative Dentistry Division, Department of Restorative Dentistry, University of Campinas, Piracicaba Dental School, Piracicaba, SP, Brazil.
Oper Dent ; 47(1): 55-63, 2022 Jan 01.
Article em En | MEDLINE | ID: mdl-35584286
ABSTRACT

OBJECTIVES:

To evaluate the effect of argon plasma treatment (PLA) when combined with sandblasting (SAN), silanization (SIL), and hydrophobic bonding resin (HBR) on the shear bond strength (SBS) of a two-year water-aged resin composite bonded to a newly placed composite after 24 hours and one year of water-storage. METHODS AND MATERIALS Thirty-six light-cured composite plates (20mm x 20mm x 4mm thick) were obtained and stored at 37°C in distilled water for 2 years. These aged plates were distributed into 6 groups (n=6) according to the surface treatment no treatment (Negative Control); SAN+SIL+HBR (Positive Control); SAN+PLA+SIL+HBR; PLA+ SIL+HBR; PLA+SIL; PLA+HBR. Fresh resin composite cylinders were built up using silicone molds (hole 1.5 mm high x 1.5 mm diameter) positioned over the aged plates. Half of the SBS samples were stored in distilled water for 24 hours and loaded until failure, while the other half were stored for 1 year before being tested. Data were submitted to two-way analysis of variance and post-hoc Tukey Test (preset alpha of 0.05).

RESULTS:

Positive Control, SAN+PLA+SIL+HBR and PLA+SIL+HBR groups presented higher SBS means at the 24 hour evaluation. After 1 year of water storage, all groups demonstrated significant SBS reduction, with the SAN+PLA+SIL+HBR group presenting the highest SBS.

CONCLUSIONS:

Resin plasma treatment in combination with other surface treatments can improve the SBS of composite repairs after one year of water storage. The SBS of the composite repair was not stable over time regardless of the surface treatment.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Colagem Dentária / Gases em Plasma Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Colagem Dentária / Gases em Plasma Idioma: En Ano de publicação: 2022 Tipo de documento: Article