Your browser doesn't support javascript.
loading
Association between oxygen saturation level during bronchoscopy and post-bronchoscopy adverse events: a retrospective cohort study.
Kim, So Yeon; Lee, Hyo Jin; Lee, Jung Kyu; Park, Tae Yeon; Heo, Eun Young; Kim, Deog Kyeom; Chung, Hee Soon; Lee, Hyun Woo.
Afiliação
  • Kim SY; Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, 20, Boramae-ro 5-gil, Dongjak-gu, Seoul, 07061, Republic of Korea.
  • Lee HJ; Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, 20, Boramae-ro 5-gil, Dongjak-gu, Seoul, 07061, Republic of Korea.
  • Lee JK; Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, 20, Boramae-ro 5-gil, Dongjak-gu, Seoul, 07061, Republic of Korea.
  • Park TY; Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, 20, Boramae-ro 5-gil, Dongjak-gu, Seoul, 07061, Republic of Korea.
  • Heo EY; Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, 20, Boramae-ro 5-gil, Dongjak-gu, Seoul, 07061, Republic of Korea.
  • Kim DK; Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, 20, Boramae-ro 5-gil, Dongjak-gu, Seoul, 07061, Republic of Korea.
  • Chung HS; Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, 20, Boramae-ro 5-gil, Dongjak-gu, Seoul, 07061, Republic of Korea.
  • Lee HW; Division of Pulmonary and Critical Care Medicine, Department of Internal Medicine, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, 20, Boramae-ro 5-gil, Dongjak-gu, Seoul, 07061, Republic of Korea. athrunzara86@snu.ac.kr.
Respir Res ; 23(1): 144, 2022 Jun 02.
Article em En | MEDLINE | ID: mdl-35655299
BACKGROUND: Flexible bronchoscopy is widely used to diagnose and treat various respiratory diseases. However, caution is warranted for post-bronchoscopy adverse events. Although desaturation frequently occurs during bronchoscopy, its clinical impact and the optimal oxygen saturation level during the procedure remain unclear. This study aimed to investigate whether the percutaneous oxygen saturation (SpO2) level during bronchoscopy is associated with the development of post-bronchoscopy respiratory adverse events. METHODS: In this single-center retrospective cohort study conducted from March 2020 to February 2021, 569 patients were classified into high or low oxygen saturation groups based on the SpO2 level during bronchoscopy. The primary outcome was post-bronchoscopy respiratory adverse events, and secondary outcomes were other post-bronchoscopy adverse events and clinical outcomes. RESULTS: Among 569 patients, 458 and 111 patients were classified into the high oxygen saturation (SpO2 > 96%) and low oxygen saturation (SpO2 ≤ 94%) groups, respectively. After propensity score matching, the low oxygen saturation group had more post-bronchoscopy respiratory and febrile adverse events than the high oxygen saturation group. In the multivariable regression analysis, low SpO2 level during bronchoscopy was an independent risk factor for post-bronchoscopy respiratory adverse events (odds ratio = 3.16 [95% confidence interval 1.37-7.30]). In the low oxygen saturation group, the high-risk subgroups for post-bronchoscopy respiratory adverse events were the elderly, women, current smokers, and patients with chronic obstructive pulmonary disease or acute decompensated heart failure before bronchoscopy. There was no significant difference in the length of hospital stay, intensive care unit admission, or mortality between the high and low oxygen saturation groups. CONCLUSIONS: Close monitoring is recommended for patients with SpO2 ≤ 94% during bronchoscopy due to the increased risk of respiratory adverse events after the procedure.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Broncoscopia / Doença Pulmonar Obstrutiva Crônica Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Broncoscopia / Doença Pulmonar Obstrutiva Crônica Tipo de estudo: Etiology_studies / Observational_studies / Risk_factors_studies Limite: Aged / Female / Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article