Evaluation of 131I transfer in the environment based on the available measurements made in Belarus after the Chernobyl accident.
J Environ Radioact
; 250: 106928, 2022 Sep.
Article
em En
| MEDLINE
| ID: mdl-35660203
This study evaluates the 131I transfer from ground deposition to the human thyroid gland after the Chernobyl accident using measurements of 131I concentrations in 1,252 soil, 124 grass, and 136 cow's milk samples as well as 131I thyroid activity measured in 3,100 individuals included in the Belarusian-American cohort. The following parameters of an 131I environmental transfer model used to calculate thyroid doses were evaluated in this study: (i) the interception factor of 131I by pasture grass, which was described by a purely empirical equation, (ii) the removal rate of 131I from pasture grass due to weathering and growth dilution, estimated to be 0.0676 d-1 (half-life of 10.3 d), (iii) the removal rate of 131I from cow's milk, estimated to be 0.0686 d-1 (half-life of 10.1 d), and (iv) the transfer coefficient of 131I from feed to cow's milk, arithmetic mean ± standard deviation of (6.7 ± 8.7) × 10-3 d L-1 (median = 4.0 × 10-3 d L-1). The individual model-based and measurement-based 131I thyroid activities for the Belarusian-American cohort members were calculated using different starting points of 131I transfer in the chain 'ground deposition' â 'vegetation' â 'cow's milk' â 'human thyroid', i.e., the measured 131I concentrations in soil, grass, and cow's milk. De novo thyroid doses from 131I for the 3,100 cohort members were calculated in this study using measured 131I activity concentrations in soil, grass, and cow's milk and were compared with those estimated previously for the same individuals using model-based 131I activity concentrations. It was shown that the use of measured instead of model-based 131I concentrations, in general, did not improve the measurement-based thyroid dose estimates. This is likely to be because there was already a good generic data base for the parameters used in this assessment. This finding indicates that, although the measurements of environmental samples are essential to estimate the parameter values of the 131I transfer model, the individual measurements of 131I thyroid activity are the most valuable information for estimating individual thyroid doses.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Monitoramento de Radiação
/
Acidente Nuclear de Chernobyl
Tipo de estudo:
Prognostic_studies
Limite:
Animals
/
Female
/
Humans
País como assunto:
Europa
Idioma:
En
Ano de publicação:
2022
Tipo de documento:
Article