Your browser doesn't support javascript.
loading
Isotropic three-dimensional dual-color super-resolution microscopy with metal-induced energy transfer.
Thiele, Jan Christoph; Jungblut, Marvin; Helmerich, Dominic A; Tsukanov, Roman; Chizhik, Anna; Chizhik, Alexey I; Schnermann, Martin J; Sauer, Markus; Nevskyi, Oleksii; Enderlein, Jörg.
Afiliação
  • Thiele JC; Third Institute of Physics-Biophysics, Georg August University, 37077 Göttingen, Germany.
  • Jungblut M; Department of Biotechnology and Biophysics, Biocenter, University of Würzburg, Am Hubland, 97074 Würzburg, Germany.
  • Helmerich DA; Department of Biotechnology and Biophysics, Biocenter, University of Würzburg, Am Hubland, 97074 Würzburg, Germany.
  • Tsukanov R; Third Institute of Physics-Biophysics, Georg August University, 37077 Göttingen, Germany.
  • Chizhik A; Third Institute of Physics-Biophysics, Georg August University, 37077 Göttingen, Germany.
  • Chizhik AI; Third Institute of Physics-Biophysics, Georg August University, 37077 Göttingen, Germany.
  • Schnermann MJ; Chemical Biology Laboratory, Center for Cancer Research, National Cancer Institute, Frederick, MD 21702, USA.
  • Sauer M; Department of Biotechnology and Biophysics, Biocenter, University of Würzburg, Am Hubland, 97074 Würzburg, Germany.
  • Nevskyi O; Third Institute of Physics-Biophysics, Georg August University, 37077 Göttingen, Germany.
  • Enderlein J; Third Institute of Physics-Biophysics, Georg August University, 37077 Göttingen, Germany.
Sci Adv ; 8(23): eabo2506, 2022 Jun 10.
Article em En | MEDLINE | ID: mdl-35675401
ABSTRACT
Over the past two decades, super-resolution microscopy has seen a tremendous development in speed and resolution, but for most of its methods, there exists a remarkable gap between lateral and axial resolution, which is by a factor of 2 to 3 worse. One recently developed method to close this gap is metal-induced energy transfer (MIET) imaging, which achieves an axial resolution down to nanometers. It exploits the distance-dependent quenching of fluorescence when a fluorescent molecule is brought close to a metal surface. In the present manuscript, we combine the extreme axial resolution of MIET imaging with the extraordinary lateral resolution of single-molecule localization microscopy, in particular with direct stochastic optical reconstruction microscopy (dSTORM). This combination allows us to achieve isotropic three-dimensional super-resolution imaging of subcellular structures. Moreover, we used spectral demixing for implementing dual-color MIET-dSTORM that allows us to image and colocalize, in three dimensions, two different cellular structures simultaneously.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article