Modular microfluidic system for on-chip extraction, preconcentration and detection of the cytokine biomarker IL-6 in biofluid.
Alexandre, Lucile; Bendali, Amel; Pereiro, Iago; Azimani, Madad; Dumas, Simon; Malaquin, Laurent; Mai, Thanh Duc; Descroix, Stéphanie.
Afiliação
  • Alexandre L; Laboratoire Physico Chimie Curie, Institut Curie, PSL Research University, CNRS UMR168, Paris, France. lucile.alexandre@curie.fr.
  • Bendali A; Institut Pierre-Gilles de Gennes, Paris, France. lucile.alexandre@curie.fr.
  • Pereiro I; Laboratoire Physico Chimie Curie, Institut Curie, PSL Research University, CNRS UMR168, Paris, France.
  • Azimani M; Institut Pierre-Gilles de Gennes, Paris, France.
  • Dumas S; Laboratoire Physico Chimie Curie, Institut Curie, PSL Research University, CNRS UMR168, Paris, France.
  • Malaquin L; Institut Pierre-Gilles de Gennes, Paris, France.
  • Mai TD; Laboratoire Physico Chimie Curie, Institut Curie, PSL Research University, CNRS UMR168, Paris, France.
  • Descroix S; Institut Pierre-Gilles de Gennes, Paris, France.
Sci Rep ; 12(1): 9468, 2022 06 08.
Article em En | MEDLINE | ID: mdl-35676309
The cytokine interleukin 6 (IL-6) is involved in the pathogenesis of different inflammatory diseases, including cancer, and its monitoring could help diagnosis, prognosis of relapse-free survival and recurrence. Here, we report an innovative microfluidic approach that uses the fluidization of magnetic beads to specifically extract, preconcentrate and fluorescently detect IL-6 directly on-chip. We assess how the physical properties of the beads can be tuned to improve assay performance by enhancing mass transport, reduce non-specific binding and multiply the detection signal threefold by transitioning between packed and fluidization states. With the integration of a full ELISA protocol in a single microfluidic chamber, we show a twofold reduction in LOD compared to conventional methods along with a large dynamic range (10 pg/mL to 2 ng/mL). We additionally demonstrate its application to IL-6 detection in undiluted serum samples.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Microfluídica / Técnicas Analíticas Microfluídicas Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Microfluídica / Técnicas Analíticas Microfluídicas Tipo de estudo: Diagnostic_studies / Guideline / Prognostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article