Your browser doesn't support javascript.
loading
Bragg coherent diffraction imaging of single 20 nm Pt particles at the ID01-EBS beamline of ESRF.
Richard, M-I; Labat, S; Dupraz, M; Li, N; Bellec, E; Boesecke, P; Djazouli, H; Eymery, J; Thomas, O; Schülli, T U; Santala, M K; Leake, S J.
Afiliação
  • Richard MI; Université Grenoble Alpes, CEA Grenoble, IRIG, MEM, NRS, 17 rue des Martyrs, 38000 Grenoble, France.
  • Labat S; ESRF - The European Synchrotron, 71 Avenue des Martyrs, 38000 Grenoble, France.
  • Dupraz M; Aix Marseille Université, CNRS, Université de Toulon, IM2NP UMR 7334, 13397 Marseille, France.
  • Li N; Université Grenoble Alpes, CEA Grenoble, IRIG, MEM, NRS, 17 rue des Martyrs, 38000 Grenoble, France.
  • Bellec E; ESRF - The European Synchrotron, 71 Avenue des Martyrs, 38000 Grenoble, France.
  • Boesecke P; Université Grenoble Alpes, CEA Grenoble, IRIG, MEM, NRS, 17 rue des Martyrs, 38000 Grenoble, France.
  • Djazouli H; ESRF - The European Synchrotron, 71 Avenue des Martyrs, 38000 Grenoble, France.
  • Eymery J; ESRF - The European Synchrotron, 71 Avenue des Martyrs, 38000 Grenoble, France.
  • Thomas O; ESRF - The European Synchrotron, 71 Avenue des Martyrs, 38000 Grenoble, France.
  • Schülli TU; ESRF - The European Synchrotron, 71 Avenue des Martyrs, 38000 Grenoble, France.
  • Santala MK; Université Grenoble Alpes, CEA Grenoble, IRIG, MEM, NRS, 17 rue des Martyrs, 38000 Grenoble, France.
  • Leake SJ; Aix Marseille Université, CNRS, Université de Toulon, IM2NP UMR 7334, 13397 Marseille, France.
J Appl Crystallogr ; 55(Pt 3): 621-625, 2022 Jun 01.
Article em En | MEDLINE | ID: mdl-35719306
Electronic or catalytic properties can be modified at the nanoscale level. Engineering efficient and specific nanomaterials requires the ability to study their complex structure-property relationships. Here, Bragg coherent diffraction imaging was used to measure the three-dimensional shape and strain of platinum nanoparticles with a diameter smaller than 30 nm, i.e. significantly smaller than any previous study. This was made possible by the realization of the Extremely Brilliant Source of ESRF, The European Synchrotron. This work demonstrates the feasibility of imaging the complex structure of very small particles in three dimensions and paves the way towards the observation of realistic catalytic particles.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2022 Tipo de documento: Article