Impact of an Electronic Decision Support Tool to Improve Ophthalmic Safety in Hydroxychloroquine Prescribing Practices.
Ophthalmic Surg Lasers Imaging Retina
; 53(6): 310-316, 2022 06.
Article
em En
| MEDLINE
| ID: mdl-35724373
BACKGROUND AND OBJECTIVE: The purpose of this study was to implement a clinical decision support tool (CDS) and assess its impact on adherence to 2016 American Academy of Ophthalmology (AAO) hydroxychloroquine dosing recommendations. PATIENTS AND METHODS: This retrospective, interventional study implemented an automated alert to calculate maximum daily hydroxychloroquine dose based on 2016 AAO recommendations and flag noncompliant orders. Prevalence of excessive dosing after CDS implementation was assessed. RESULTS: A total of 7,417 patients met inclusion criteria. After intervention, prevalence of excessive dosing decreased from 27.4% to 21.1% (P < .001) among all prescriptions and from 26.8% to 16.2% (P < .001) among new prescriptions. Daily doses exceeding 400 mg decreased from 0.8% to 0.02% (P < .001). Risk factors for excessive dosing included low weight (odds ratio, 75.6 [95% CI, 54.0 to 105.8]) and nonrheumatologist prescriber (odds ratio, 1.60 to 3.63; all P < .005). CONCLUSIONS: This study highlights the efficacy of a CDS in reducing excessive hydroxychloroquine dosing and improving adherence to AAO ophthalmic safety guidelines. [Ophthalmic Surg Lasers Imaging 2022;53:310-316.].
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Oftalmologia
/
Antirreumáticos
Tipo de estudo:
Guideline
/
Observational_studies
/
Prognostic_studies
/
Risk_factors_studies
Limite:
Humans
País como assunto:
America do norte
Idioma:
En
Ano de publicação:
2022
Tipo de documento:
Article