Design of a Lab-On-Chip for Cancer Cell Detection through Impedance and Photoelectrochemical Response Analysis.
Hsiao, Yu-Ping; Mukundan, Arvind; Chen, Wei-Chung; Wu, Ming-Tsang; Hsieh, Shang-Chin; Wang, Hsiang-Chen.
Afiliação
  • Hsiao YP; Department of Dermatology, Chung Shan Medical University Hospital, No.110, Sec. 1, Jianguo N. Rd., South District, Taichung City 40201, Taiwan.
  • Mukundan A; Institute of Medicine, School of Medicine, Chung Shan Medical University, No.110, Sec. 1, Jianguo N. Rd., South District, Taichung City 40201, Taiwan.
  • Chen WC; Department of Mechanical Engineering, Advanced Institute of Manufacturing with High Tech Innovations (AIM-HI), Center for Innovative Research on Aging Society (CIRAS), National Chung Cheng University, 168, University Rd., Min Hsiung, Chia Yi 62102, Taiwan.
  • Wu MT; Ph.D. Program in Environmental and Occupational Medicine, Kaohsiung Medical University, Kaohsiung 807377, Taiwan.
  • Hsieh SC; Ph.D. Program in Environmental and Occupational Medicine, Kaohsiung Medical University, Kaohsiung 807377, Taiwan.
  • Wang HC; Research Center for Environmental Medicine, Kaohsiung Medical University, Kaohsiung 807377, Taiwan.
Biosensors (Basel) ; 12(6)2022 Jun 13.
Article em En | MEDLINE | ID: mdl-35735553
ABSTRACT
In this study, a biochip was fabricated using a light-absorbing layer of a silicon solar element combined with serrated, interdigitated electrodes and used to identify four different types of cancer cells CE81T esophageal cancer, OE21 esophageal cancer, A549 lung adenocarcinoma, and TSGH-8301 bladder cancer cells. A string of pearls was formed from dielectrophoretic aggregated cancer cells because of the serrated interdigitated electrodes. Thus, cancer cells were identified in different parts, and electron-hole pairs were separated by photo-excited carriers through the light-absorbing layer of the solar element. The concentration catalysis mechanism of GSH and GSSG was used to conduct photocurrent response and identification, which provides the fast, label-free measurement of cancer cells. The total time taken for this analysis was 13 min. Changes in the impedance value and photocurrent response of each cancer cell were linearly related to the number of cells, and the slope of the admittance value was used to distinguish the location of the cancerous lesion, the slope of the photocurrent response, and the severity of the cancerous lesion. The results show that the number of cancerous cells was directly proportional to the admittance value and the photocurrent response for all four different types of cancer cells. Additionally, different types of cancer cells could easily be differentiated using the slope value of the photocurrent response and the admittance value.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Silício / Neoplasias Esofágicas Tipo de estudo: Diagnostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article