Automatic evaluation of graft orientation during Descemet membrane endothelial keratoplasty using intraoperative OCT.
Muijzer, Marc B; Heslinga, Friso G; Couwenberg, Floor; Noordmans, Herke-Jan; Oahalou, Abdelkarim; Pluim, Josien P W; Veta, Mitko; Wisse, Robert P L.
Afiliação
  • Muijzer MB; Utrecht Cornea Research Group, Ophthalmology Department, University Medical Center Utrecht, Heidelberglaan 100, 3584CX, Utrecht, The Netherlands.
  • Heslinga FG; Contributed equally.
  • Couwenberg F; Department of Biomedical Engineering, Eindhoven University of Technology, Postbus 513, 5600 MB, Eindhoven, The Netherlands.
  • Noordmans HJ; Contributed equally.
  • Oahalou A; University of Twente, Drienerlolaan 5, 7522 NB Enschede, The Netherlands.
  • Pluim JPW; Medical technical and Clinical physics department, University Medical Center Utrecht, Heidelberglaan 100, 3584CX, Utrecht, The Netherlands.
  • Veta M; Ophthalmology Department, Gelre Hospitals, Apeldoorn, The Netherlands.
  • Wisse RPL; Department of Biomedical Engineering, Eindhoven University of Technology, Postbus 513, 5600 MB, Eindhoven, The Netherlands.
Biomed Opt Express ; 13(5): 2683-2694, 2022 May 01.
Article em En | MEDLINE | ID: mdl-35774322
Correct Descemet Membrane Endothelial Keratoplasty (DMEK) graft orientation is imperative for success of DMEK surgery, but intraoperative evaluation can be challenging. We present a method for automatic evaluation of the graft orientation in intraoperative optical coherence tomography (iOCT), exploiting the natural rolling behavior of the graft. The method encompasses a deep learning model for graft segmentation, post-processing to obtain a smooth line representation, and curvature calculations to determine graft orientation. For an independent test set of 100 iOCT-frames, the automatic method correctly identified graft orientation in 78 frames and obtained an area under the receiver operating characteristic curve (AUC) of 0.84. When we replaced the automatic segmentation with the manual masks, the AUC increased to 0.92, corresponding to an accuracy of 86%. In comparison, two corneal specialists correctly identified graft orientation in 90% and 91% of the iOCT-frames.

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Prognostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article