Evaluation of the robustness of cerebral oximetry to variations in skin pigmentation using a tissue-simulating phantom.
Afshari, Ali; Saager, Rolf B; Burgos, David; Vogt, William C; Wang, Jianting; Mendoza, Gonzalo; Weininger, Sandy; Sung, Kung-Bin; Durkin, Anthony J; Pfefer, T Joshua.
Afiliação
  • Afshari A; Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA.
  • Saager RB; Linköping Univ., Dept. of Biomedical Engineering, Linköping, Sweden.
  • Burgos D; Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA.
  • Vogt WC; Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA.
  • Wang J; Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA.
  • Mendoza G; Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA.
  • Weininger S; Center for Devices and Radiological Health, Food and Drug Administration, 10903 New Hampshire Ave., Silver Spring, Maryland 20993, USA.
  • Sung KB; National Taiwan University, Graduate Institute of Biomedical Electronics and Bioinformatics, Taipei, Taiwan.
  • Durkin AJ; Department of Biomedical Engineering, University of California, Irvine, 3120 Natural Sciences II, Irvine, California 92697, USA.
  • Pfefer TJ; Beckman Laser Institute & Medical Clinic, University of California, Irvine, 1002 Health Sciences Rd. East Irvine, California 92617, USA.
Biomed Opt Express ; 13(5): 2909-2928, 2022 May 01.
Article em En | MEDLINE | ID: mdl-35774336
ABSTRACT
Clinical studies have demonstrated that epidermal pigmentation level can affect cerebral oximetry measurements. To evaluate the robustness of these devices, we have developed a phantom-based test method that includes an epidermis-simulating layer with several melanin concentrations and a 3D-printed cerebrovascular module. Measurements were performed with neonatal, pediatric and adult sensors from two commercial oximeters, where neonatal probes had shorter source-detector separation distances. Referenced blood oxygenation levels ranged from 30 to 90%. Cerebral oximeter outputs exhibited a consistent decrease in saturation level with simulated melanin content; this effect was greatest at low saturation levels, producing a change of up to 15%. Dependence on pigmentation was strongest in a neonatal sensor, possibly due to its high reflectivity. Overall, our findings indicate that a modular channel-array phantom approach can provide a practical tool for assessing the impact of skin pigmentation on cerebral oximeter performance and that modifications to algorithms and/or instrumentation may be needed to mitigate pigmentation bias.