Automated classification of otitis media with OCT: augmenting pediatric image datasets with gold-standard animal model data.
Monroy, Guillermo L; Won, Jungeun; Shi, Jindou; Hill, Malcolm C; Porter, Ryan G; Novak, Michael A; Hong, Wenzhou; Khampang, Pawjai; Kerschner, Joseph E; Spillman, Darold R; Boppart, Stephen A.
Afiliação
  • Monroy GL; Beckman Institute for Advanced Science and Technology, 405 N Mathews Ave, Urbana, IL 61801, USA.
  • Won J; Beckman Institute for Advanced Science and Technology, 405 N Mathews Ave, Urbana, IL 61801, USA.
  • Shi J; Department of Bioengineering, University of Illinois at Urbana-Champaign, 1406 W Green St, Urbana, IL 61801, USA.
  • Hill MC; Beckman Institute for Advanced Science and Technology, 405 N Mathews Ave, Urbana, IL 61801, USA.
  • Porter RG; Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, 306 N Wright St, Urbana, IL 61801, USA.
  • Novak MA; Carle Foundation Hospital, 611 W Park St., Urbana, IL 61801, USA.
  • Hong W; Carle Foundation Hospital, 611 W Park St., Urbana, IL 61801, USA.
  • Khampang P; Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, 506 S. Mathews Ave., Urbana, IL 61801, USA.
  • Kerschner JE; Carle Foundation Hospital, 611 W Park St., Urbana, IL 61801, USA.
  • Spillman DR; Carle Illinois College of Medicine, University of Illinois at Urbana-Champaign, 506 S. Mathews Ave., Urbana, IL 61801, USA.
  • Boppart SA; Department of Otolaryngology and Communication Sciences, Medical College of Wisconsin, Milwaukee, WI 53226, USA.
Biomed Opt Express ; 13(6): 3601-3614, 2022 Jun 01.
Article em En | MEDLINE | ID: mdl-35781950
Otitis media (OM) is an extremely common disease that affects children worldwide. Optical coherence tomography (OCT) has emerged as a noninvasive diagnostic tool for OM, which can detect the presence and quantify the properties of middle ear fluid and biofilms. Here, the use of OCT data from the chinchilla, the gold-standard OM model for the human disease, is used to supplement a human image database to produce diagnostically relevant conclusions in a machine learning model. Statistical analysis shows the datatypes are compatible, with a blended-species model reaching ∼95% accuracy and F1 score, maintaining performance while additional human data is collected.