Your browser doesn't support javascript.
loading
3D-printed lightweight dorsal skin fold chambers from PEEK reduce chamber-related animal distress.
Xie, Wentao; Lorenz, Matthias; Poosch, Friederike; Palme, Rupert; Zechner, Dietmar; Vollmar, Brigitte; Grambow, Eberhard; Strüder, Daniel.
Afiliação
  • Xie W; Institute for Experimental Surgery, Rostock University Medical Center, 18057, Rostock, Germany.
  • Lorenz M; Department of Vascular and Thyroid Surgery, Department of General Surgery, The First Affiliated Hospital of Anhui Medical University, Hefei, 230022, China.
  • Poosch F; Faculty of Engineering, Technology, Business and Design, University of Applied Sciences, 23966, Wismar, Germany.
  • Palme R; Department of Otorhinolaryngology, Head and Neck Surgery "Otto Koerner", Rostock University Medical Center, 18057, Rostock, Germany.
  • Zechner D; Unit of Physiology, Pathophysiology and Experimental Endocrinology, Department of Biomedical Sciences, University of Veterinary Medicine Vienna, 1210, Vienna, Austria.
  • Vollmar B; Institute for Experimental Surgery, Rostock University Medical Center, 18057, Rostock, Germany.
  • Grambow E; Institute for Experimental Surgery, Rostock University Medical Center, 18057, Rostock, Germany.
  • Strüder D; Institute for Experimental Surgery, Rostock University Medical Center, 18057, Rostock, Germany. eberhard.grambow@med.uni-rostock.de.
Sci Rep ; 12(1): 11599, 2022 07 08.
Article em En | MEDLINE | ID: mdl-35803979
ABSTRACT
The dorsal skinfold chamber is one of the most important in vivo models for repetitive longitudinal assessment of microcirculation and inflammation. This study aimed to refine this model by introducing a new lightweight chamber made from polyetheretherketone (PEEK). Body weight, burrowing activity, distress, faecal corticosterone metabolites and the tilting angle of the chambers were analysed in mice carrying either a standard titanium chamber or a PEEK chamber. Data was obtained before chamber preparation and over a postoperative period of three weeks. In the early postoperative phase, reduced body weight and increased faecal corticosterone metabolites were found in mice with titanium chambers. Chamber tilting and tilting-related complications were reduced in mice with PEEK chambers. The distress score was significantly increased in both groups after chamber preparation, but only returned to preoperative values in mice with PEEK chambers. In summary, we have shown that light chambers reduce animal distress and may extend the maximum dorsal skinfold chamber observation time. Chambers made of PEEK are particularly suitable for this

purpose:

They are autoclavable, sufficiently stable to withstand rodent bites, inexpensive, and widely available through 3D printing.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Titânio / Corticosterona Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Titânio / Corticosterona Tipo de estudo: Prognostic_studies Limite: Animals Idioma: En Ano de publicação: 2022 Tipo de documento: Article