Your browser doesn't support javascript.
loading
Quantitation of the ataxia-telangiectasia-mutated and Rad3-related inhibitor elimusertib (BAY-1895344) in human plasma using LC-MS/MS.
Kiesel, Brian F; Parise, Robert A; Krishnamurthy, Anuradha; Gore, Steven; Beumer, Jan H.
Afiliação
  • Kiesel BF; Cancer Therapeutics Program, UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA.
  • Parise RA; Department of Pharmaceutical Sciences, School of Pharmacy, University of Pittsburgh, Pittsburgh, Pennsylvania, USA.
  • Krishnamurthy A; Cancer Therapeutics Program, UPMC Hillman Cancer Center, Pittsburgh, Pennsylvania, USA.
  • Gore S; Division of Hematology-Oncology, Department of Medicine, University of Pittsburgh School of Medicine, Pittsburgh, Pennsylvania, USA.
  • Beumer JH; Investigational Drug Branch, Cancer Therapy Evaluation Program, Division of Cancer Treatment and Diagnosis, National Cancer Institute, Bethesda, Maryland, USA.
Biomed Chromatogr ; 36(11): e5455, 2022 Nov.
Article em En | MEDLINE | ID: mdl-35876841
ABSTRACT
Ataxia-telangiectasia-mutated and Rad3-related (ATR) is master regulator of the DNA-damage response that, through multiple mechanisms, can promote cancer cell survival in response to replication stress from sources, including chemotherapy and radiation. Elimusertib (BAY-1895344) is an orally available small-molecule ATR inhibitor currently in preclinical and clinical development for cancer treatment. To support these studies and define elimusertib pharmacokinetics, we developed a HPLC-MS method for its quantitation. A 50-µL volume of plasma was subjected to acetonitrile protein precipitation and then chromatographic separation using a Phenomenex Polar-RP column (2 × 50 mm, 4 µm) and a gradient mobile phase consisting of 0.1% formic acid in acetonitrile and water during a 7-min run time. Mass spectrometric detection was achieved using a SCIEX 4000 triple-stage mass spectrometer with electrospray positive-mode ionization. With a stable isotopic internal standard, the assay was linear from 30 to 5000 ng/mL and proved to be both accurate (93.5-108.2%) and precise (<6.3% coefficient of variation) fulfilling criteria from the Food and Drug Administration guidance on bioanalytical method validation. This LC-MS/MS assay will support several ongoing clinical studies by defining elimusertib pharmacokinetics.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ataxia Telangiectasia / Espectrometria de Massas em Tandem Tipo de estudo: Guideline Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ataxia Telangiectasia / Espectrometria de Massas em Tandem Tipo de estudo: Guideline Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article