Your browser doesn't support javascript.
loading
MELIF, a Fully Automated Liver Function Score Calculated from Gd-EOB-DTPA-Enhanced MR Images: Diagnostic Performance vs. the MELD Score.
Río Bártulos, Carolina; Senk, Karin; Bade, Ragnar; Schumacher, Mona; Plath, Jan; Kaiser, Nico; Wiesinger, Isabel; Thurn, Sylvia; Stroszczynski, Christian; El Mountassir, Abdelouahed; Planert, Mathis; Woetzel, Jan; Wiggermann, Philipp.
Afiliação
  • Río Bártulos C; Institut für Röntgendiagnostik und Nuklearmedizin, Städtisches Klinikum Braunschweig gGmbH, 38126 Braunschweig, Germany.
  • Senk K; Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, 93053 Regensburg, Germany.
  • Bade R; MeVis Medical Solutions AG, 28359 Bremen, Germany.
  • Schumacher M; MeVis Medical Solutions AG, 28359 Bremen, Germany.
  • Plath J; MeVis Medical Solutions AG, 28359 Bremen, Germany.
  • Kaiser N; MeVis Medical Solutions AG, 28359 Bremen, Germany.
  • Wiesinger I; Institut für Neuroradiologie, Medbo Bezirksklinikum Regensburg, 93053 Regensburg, Germany.
  • Thurn S; Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, 93053 Regensburg, Germany.
  • Stroszczynski C; Institut für Röntgendiagnostik, Universitätsklinikum Regensburg, 93053 Regensburg, Germany.
  • El Mountassir A; Institut für Röntgendiagnostik und Nuklearmedizin, Städtisches Klinikum Braunschweig gGmbH, 38126 Braunschweig, Germany.
  • Planert M; Institut für Röntgendiagnostik und Nuklearmedizin, Städtisches Klinikum Braunschweig gGmbH, 38126 Braunschweig, Germany.
  • Woetzel J; MeVis Medical Solutions AG, 28359 Bremen, Germany.
  • Wiggermann P; Institut für Röntgendiagnostik und Nuklearmedizin, Städtisches Klinikum Braunschweig gGmbH, 38126 Braunschweig, Germany.
Diagnostics (Basel) ; 12(7)2022 Jul 20.
Article em En | MEDLINE | ID: mdl-35885653
In the management of patients with chronic liver disease, the assessment of liver function is essential for treatment planning. Gd-EOB-DTPA-enhanced MRI allows for both the acquisition of anatomical information and regional liver function quantification. The objective of this study was to demonstrate and evaluate the diagnostic performance of two fully automatically generated imaging-based liver function scores that take the whole liver into account. T1 images from the native and hepatobiliary phases and the corresponding T1 maps from 195 patients were analyzed. A novel artificial-intelligence-based software prototype performed image segmentation and registration, calculated the reduction rate of the T1 relaxation time for the whole liver (rrT1liver) and used it to calculate a personalized liver function score, then generated a unified score-the MELIF score-by combining the liver function score with a patient-specific factor that included weight, height and liver volume. Both scores correlated strongly with the MELD score, which is used as a reference for global liver function. However, MELIF showed a stronger correlation than the rrT1liver score. This study demonstrated that the fully automated determination of total liver function, regionally resolved, using MR liver imaging is feasible, providing the opportunity to use the MELIF score as a diagnostic marker in future prospective studies.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Observational_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Observational_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article