New Generation Express View: An Artificial Intelligence Software Effectively Reduces Capsule Endoscopy Reading Times.
Piccirelli, Stefania; Mussetto, Alessandro; Bellumat, Angelo; Cannizzaro, Renato; Pennazio, Marco; Pezzoli, Alessandro; Bizzotto, Alessandra; Fusetti, Nadia; Valiante, Flavio; Hassan, Cesare; Pecere, Silvia; Koulaouzidis, Anastasios; Spada, Cristiano.
Afiliação
  • Piccirelli S; Fondazione Poliambulanza Istituto Ospedaliero, 25124 Brescia, Italy.
  • Mussetto A; Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, 00168 Rome, Italy.
  • Bellumat A; Ospedale Santa Maria delle Croci, 48121 Ravenna, Italy.
  • Cannizzaro R; Ospedale di Feltre, 32032 Feltre, Italy.
  • Pennazio M; Centro di Riferimento Oncologico, IRCCS, 33081 Aviano, Italy.
  • Pezzoli A; Division of Gastroenterology, University City of Health and Science University Hospital, 10121 Turin, Italy.
  • Bizzotto A; Endoscopy Unit, Department of Gastroenterology, Sant'Anna University Hospital, 44121 Ferrara, Italy.
  • Fusetti N; Fondazione Poliambulanza Istituto Ospedaliero, 25124 Brescia, Italy.
  • Valiante F; Endoscopy Unit, Department of Gastroenterology, Sant'Anna University Hospital, 44121 Ferrara, Italy.
  • Hassan C; Ospedale di Feltre, 32032 Feltre, Italy.
  • Pecere S; Endoscopy Unit, Department of Gastroenterology, IRCCS Humanitas Research Hospital, 20089 Rozzano, Italy.
  • Koulaouzidis A; Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, 00168 Rome, Italy.
  • Spada C; Digestive Endoscopy Unit, Fondazione Policlinico Universitario A. Gemelli IRCCS, 00168 Rome, Italy.
Diagnostics (Basel) ; 12(8)2022 Jul 22.
Article em En | MEDLINE | ID: mdl-35892494
BACKGROUND: Reading capsule endoscopy (CE) is time-consuming. The Express View (EV) (IntroMedic, Seoul, Korea) software was designed to shorten CE video reading. Our primary aim was to evaluate the diagnostic accuracy of EV in detecting significant small-bowel (SB) lesions. We also compared the reading times with EV mode and standard reading (SR). METHODS: 126 patients with suspected SB bleeding and/or suspected neoplasia were prospectively enrolled and underwent SB CE (MiroCam®1200, IntroMedic, Seoul, Korea). CE evaluation was performed in standard and EV mode. In case of discrepancies between SR and EV readings, a consensus was reached after reviewing the video segments and the findings were re-classified. RESULTS: The completion rate of SB CE in our cohort was 86.5% and no retention occurred. The per-patient analysis of sensitivity, specificity, positive predictive value, negative predictive value, and diagnostic accuracy of EV compared to SR were 86%, 86%, 90%, 81%, and 86%, respectively, before consensus. After consensus, they increased to 97%, 100%, 100%, 96%, and 98%, respectively. The median reading time with SR and EV was 71 min (range 26−340) and 13 min (range 3−85), respectively (p < 0.001). CONCLUSIONS: The new-generation EV shows high diagnostic accuracy and significantly reduces CE reading times.