Your browser doesn't support javascript.
loading
Semi-experimental assessment of neutron equivalent dose and secondary cancer risk for off-field organs in glioma patients undergoing 18-MV radiotherapy.
Elmtalab, Soheil; Abedi, Iraj; Alirezaei, Zahra; Choopan Dastjerdi, Mohammad Hossein; Geraily, Ghazale; Karimi, Amir Hossein.
Afiliação
  • Elmtalab S; Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
  • Abedi I; Department of Medical Physics, School of Medicine, Isfahan University of Medical Sciences, Isfahan, Iran.
  • Alirezaei Z; School of Paramedicine, Bushehr University of Medical Sciences, Bushehr, Iran.
  • Choopan Dastjerdi MH; Reactor and Nuclear Safety Research School, Nuclear Science and Technology Research Institute, Isfahan, Iran.
  • Geraily G; Radiation Oncology Research Center, Cancer Institute, Tehran University of Medical Sciences, Tehran, Iran.
  • Karimi AH; Department of Medical Physics and Biomedical Engineering, School of Medicine, Tehran University of Medical Sciences, Tehran, Iran.
PLoS One ; 17(7): e0271028, 2022.
Article em En | MEDLINE | ID: mdl-35905102
ABSTRACT
Neutron contamination as a source of out-of-field dose in radiotherapy is still of concern. High-energy treatment photons have the potential to overcome the binding energy of neutrons inside the nuclei. Fast neutrons emitting from the accelerator head can directly reach the patient's bed. Considering that modern radiotherapy techniques can increase patient survival, concerns about unwanted doses and the lifetime risk of fatal cancer remain strong or even more prominent, especially in young adult patients. The current study addressed these concerns by quantifying the dose and risk of fatal cancer due to photo-neutrons for glioma patients undergoing 18-MV radiotherapy. In this study, an NRD model rem-meter detector was used to measure neutron ambient dose equivalent, H*(10), at the patient table. Then, the neutron equivalent dose received by each organ was estimated concerning the depth of each organ and by applying depth dose corrections to the measured H*(10). Finally, the effective dose and risk of secondary cancer were determined using NCRP 116 coefficients. Evidence revealed that among all organs, the breast (0.62 mSv/Gy) and gonads (0.58 mSv/Gy) are at risk of photoneutrons more than the other organs in such treatments. The neutron effective dose in the 18-MV conventional radiotherapy of the brain was 13.36 mSv. Among all organs, gonads (6.96 mSv), thyroid (1.86 mSv), and breasts (1.86 mSv) had more contribution to the effective dose, respectively. The total secondary cancer risk was estimated as 281.4 cases (per 1 million persons). The highest risk was related to the breast and gonads with 74.4 and, 34.8 cases per 1 million persons, respectively. Therefore, it is recommended that to prevent late complications (secondary cancer and genetic effects), these organs should be shielded from photoneutrons. This procedure not only improves the quality of the patient's personal life but also the healthy childbearing in the community.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Segunda Neoplasia Primária / Glioma Tipo de estudo: Etiology_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Segunda Neoplasia Primária / Glioma Tipo de estudo: Etiology_studies / Risk_factors_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article