Diagnostic performance of the 2021 Korean thyroid imaging reporting and data system in pediatric thyroid nodules.
Eur Radiol
; 33(1): 172-180, 2023 Jan.
Article
em En
| MEDLINE
| ID: mdl-35976400
OBJECTIVES: To evaluate the diagnostic performance of 2021 K-TIRADS biopsy criteria for detecting malignant thyroid nodules in a pediatric population, making comparisons with 2016 K-TIRADS. METHODS: This retrospective study included pediatric patients with histopathologically confirmed diagnoses. The diagnostic performance of 2021 K-TIRADS was compared with that of 2016 K-TIRADS. Simulation studies were performed by changing biopsy cut-off sizes for K-TIRADS 5 to 1.0 cm (K-TIRADS5-1.0cm) and 0.5 cm (K-TIRADS5-0.5cm), and for K-TIRADS 4 to 1.0 cm (K-TIRADS4-1.0cm) and 1.0-1.5 cm (K-TIRADS4-1.0~1.5cm). Subgroup analysis was performed in small (< 1.5 cm) and large nodules (≥ 1.5 cm). RESULTS: Two hundred seventy-seven thyroid nodules (54.9% malignant) from 221 pediatric patients were analyzed. All simulated 2021 K-TIRADS showed higher accuracy than 2016 K-TIRADS. Compared with 2021 K-TIRADS5-1.0cm, 2021 K-TIRADS5-0.5cm showed lower specificity (51.6% vs. 47.9%; p = 0.004) but higher sensitivity (77.2% vs. 90.3%; p < 0.001) and accuracy (62.7% vs. 68.9%; p < 0.001). Compared with 2021 K-TIRADS4-1.0cm, 2021 K-TIRADS4-1.0~1.5cm showed higher specificity (44.9% vs. 47.9%; p = 0.018) without significant difference in other diagnostic measures. Compared with 2016 K-TIRADS, 2021 K-TIRADS (biopsy cut-offs, 0.5 cm for K-TIRADS 5; 1.0-1.5 cm for K-TIRADS 4) showed higher sensitivity (34.0% vs. 67.3%; p < 0.001) while maintaining specificity (89.4% vs. 88.2%; p = 0.790) in small nodules, and higher specificity (5.9% vs. 25.4%; p < 0.001) while maintaining sensitivity (100% vs. 98.7%; p = 0.132) in large nodules. CONCLUSIONS: In pediatric patients, 2021 K-TIRADS showed superior diagnostic accuracy to 2016 K-TIRADS, especially with a biopsy cut-off of 0.5 cm for K-TIRADS 5 and 1.0-1.5 cm for K-TIRADS 4. KEY POINTS: ⢠All simulated 2021 K-TIRADS showed higher accuracy than 2016 K-TIRADS. ⢠2021 K-TIRADS with cut-off size for K-TIRADS 5 of 0.5 cm showed lower specificity but higher sensitivity and accuracy than that of 1.0 cm. ⢠Compared with 2016 K-TIRADS, 2021 K-TIRADS (biopsy cut-offs, 0.5 cm for K-TIRADS 5; 1.0-1.5 cm for K-TIRADS 4) showed higher sensitivity while maintaining specificity in small nodules, and higher specificity while maintaining sensitivity in large nodules.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Neoplasias da Glândula Tireoide
/
Nódulo da Glândula Tireoide
Tipo de estudo:
Diagnostic_studies
/
Observational_studies
Limite:
Child
/
Humans
País como assunto:
Asia
Idioma:
En
Ano de publicação:
2023
Tipo de documento:
Article