Your browser doesn't support javascript.
loading
An in-silicoanalysis of retinal electric field distribution induced by different electrode design of trans-corneal electrical stimulation.
Lu, Zhuofan; Zhou, Meixuan; Guo, Tianruo; Liang, Junling; Wu, Weilei; Gao, Qi; Li, Liming; Li, Heng; Chai, Xinyu.
Afiliação
  • Lu Z; School of Biomedical Engineering, Shanghai Jiao Tong University, 200240 Shanghai, People's Republic of China.
  • Zhou M; School of Biomedical Engineering, Shanghai Jiao Tong University, 200240 Shanghai, People's Republic of China.
  • Guo T; Graduate School of Biomedical Engineering, University of New South Wales, NSW 2052 Sydney, Australia.
  • Liang J; School of Biomedical Engineering, Shanghai Jiao Tong University, 200240 Shanghai, People's Republic of China.
  • Wu W; School of Biomedical Engineering, Shanghai Jiao Tong University, 200240 Shanghai, People's Republic of China.
  • Gao Q; School of Biomedical Engineering, Shanghai Jiao Tong University, 200240 Shanghai, People's Republic of China.
  • Li L; School of Biomedical Engineering, Shanghai Jiao Tong University, 200240 Shanghai, People's Republic of China.
  • Li H; School of Biomedical Engineering, Shanghai Jiao Tong University, 200240 Shanghai, People's Republic of China.
  • Chai X; School of Biomedical Engineering, Shanghai Jiao Tong University, 200240 Shanghai, People's Republic of China.
J Neural Eng ; 19(5)2022 09 14.
Article em En | MEDLINE | ID: mdl-36044887
ABSTRACT
Objective.Trans-corneal electrical stimulation (TcES) produces therapeutic effects on many ophthalmic diseases non-invasively. Existing clinical TcES devices use largely variable design of electrode distribution and stimulation parameters. Better understanding of how electrode configuration paradigms and stimulation parameters influence the electric field distribution on the retina, will be beneficial to the design of next-generation TcES devices.Approach.In this study, we constructed a realistic finite element human head model with fine eyeball structure. Commonly used DTL-Plus and ERG-Jet electrodes were simulated. We then conductedin silicoinvestigations of retina observation surface (ROS) electric field distributions induced by different return electrode configuration paradigms and different stimulus intensities.Main results.Our results suggested that the ROS electric field distribution could be modulated by re-designing TcES electrode settings and stimulus parameters. Under far return location paradigms, either DTL-Plus or ERG-Jet approach could induce almost identical ROS electric field distribution regardless where the far return was located. However, compared with the ERG-Jet mode, DTL-Plus stimulation induced stronger nasal lateralization. In contrast, ERG-Jet stimulation induced relatively stronger temporal lateralization. The ROS lateralization can be further tweaked by changing the DTL-Plus electrode length.Significance.These results may contribute to the understanding of the characteristics of DTL-Plus and ERG-Jet electrodes based electric field distribution on the retina, providing practical implications for the therapeutic application of TcES.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Retina / Eletrorretinografia Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Retina / Eletrorretinografia Tipo de estudo: Prognostic_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article