Your browser doesn't support javascript.
loading
Facial scanning technologies in the era of digital workflow: A systematic review and network meta-analysis.
Antonacci, Donato; Caponio, Vito Carlo Alberto; Troiano, Giuseppe; Pompeo, Mario Giulio; Gianfreda, Francesco; Canullo, Luigi.
Afiliação
  • Antonacci D; Private Practice, Via Leonida Laforgia, Bari, Italy.
  • Caponio VCA; Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy.
  • Troiano G; Department of Clinical and Experimental Medicine, University of Foggia, Foggia, Italy.
  • Pompeo MG; Private Practice, Rome, Italy.
  • Gianfreda F; Department of Industrial Engineering, University of Rome "Tor Vergata", Rome, Italy.
  • Canullo L; Department of Periodontology, University of Bern, Switzerland.
J Prosthodont Res ; 67(3): 321-336, 2023 Jul 31.
Article em En | MEDLINE | ID: mdl-36058870
ABSTRACT

PURPOSE:

The aim of this network meta-analysis is to evaluate the accuracy of various face-scanning technologies in the market, with respect to the different dimensions of space (x, y, and z axes). Furthermore, attention will be paid to the type of technologies currently used and to the best practices for high-quality scan acquisition. MATERIAL AND

METHODS:

The review was conducted following the PRISMA guidelines and its updates. A thorough search was performed using the digital databases MEDLINE, PubMed, EMBASE, and the Cochrane Central Register of Controlled Trials by entering research lines or various combinations of free words. The main keywords used during the search process were "photogrammetry", "laser scanner", "optical scanner", "3D", and "face".

RESULTS:

None of the included technologies significantly deviated from direct anthropometry. The obtained mean differences in the distances between the considered landmarks range from 1.10 to -1.74 mm.

CONCLUSIONS:

Limiting the movements of the patient and scanner allows for more accurate facial scans with all the technologies involved. Active technologies such as laser scanners (LS), structured light (SL), and infrared structured light (ISL) have accuracy comparable to that of static stereophotogrammetry while being more cost-effective and less time-consuming.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fotogrametria / Imageamento Tridimensional Tipo de estudo: Guideline / Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fotogrametria / Imageamento Tridimensional Tipo de estudo: Guideline / Systematic_reviews Limite: Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article