Functional nodules in primary aldosteronism: identification of CXCR4 expression with 68Ga-pentixafor PET/CT.
Eur Radiol
; 33(2): 996-1003, 2023 Feb.
Article
em En
| MEDLINE
| ID: mdl-36070092
OBJECTIVES: We analyzed the diagnostic efficiency of 68Ga-pentixafor PET/CT for functional nodules in primary aldosteronism (PA). Furthermore, we compared the correlation of CXCR4 expression with aldosterone synthase (CYP11B2) expression and PET/CT uptake in these patients. METHODS: We prospectively assessed 50 patients diagnosed with PA and 10 patients with non-functional adrenal adenoma (NFA). All patients underwent 68Ga-pentixafor PET/CT before adrenalectomy. Immunohistochemistry (IHC) was performed to detect the protein expression of CYP11B2 and the G-protein-coupled receptor CXCR4. RESULTS: CYP11B2 IHC revealed the presence of 43 functional nodules. Subsequently, 40/43 functional nodules could be detected on 68Ga-pentixafor PET/CT, while negative imaging findings were noted for 11/13 non-functional nodules (sensitivity, 93.0%; specificity, 84.6%). The optimum SUVmax cut-off for the identification of functional nodules was 8.95 (AUC 0.914 [0.828-1.000], p < 0.001). Regarding the size of functional nodules, diagnostic efficiency appeared to be much higher for nodules greater than 1 cm in size (sensitivity, up to 97.3%). Moreover, we examined the relationship between CXCR4 and CYP11B2 expression in 56 lesions. All 43 CYP11B2-positive nodules were CXCR4-positive, but one of the 13 CYP11B2-negative nodules (7.7%) showed false-positive staining for CXCR4. Moreover, the consistency between PET/CT uptake and CXCR4 staining results was 92.9% (52/56). CONCLUSIONS: At least 90% of functional nodules show positive uptake on 68Ga-pentixafor PET/CT, and the detection ability is much better for nodules with a diameter ≥ 1 cm. With its high sensitivity and specificity, 68Ga-pentixafor PET/CT can be considered a promising surgical decision-making tool for patients with PA. KEY POINTS: ⢠68Ga-pentixafor PET/CT could be a useful tool for the identification of functional adrenal nodules in APAs and even IHAs. ⢠The diagnostic efficiency appears to be much higher for nodules ≥ 1 cm in size. ⢠There is high consistency between the results of 68Ga-pentixafor PET/CT imaging and CXCR4 immunohistochemistry.
Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada
/
Hiperaldosteronismo
Tipo de estudo:
Diagnostic_studies
/
Prognostic_studies
Limite:
Humans
Idioma:
En
Ano de publicação:
2023
Tipo de documento:
Article