Your browser doesn't support javascript.
loading
Point-of-Care Immunoassay Based on a Multipixel Dual-Channel Pressure Sensor Array with Visual Sensing Capability of Full-Color Switching and Reliable Electrical Signals.
Huang, Lingting; Zeng, Ruijin; Xu, Jianhui; Tang, Dianping.
Afiliação
  • Huang L; Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China.
  • Zeng R; Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China.
  • Xu J; Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China.
  • Tang D; Key Laboratory for Analytical Science of Food Safety and Biology (MOE & Fujian Province), Department of Chemistry, Fuzhou University, Fuzhou 350108, People's Republic of China.
Anal Chem ; 94(38): 13278-13286, 2022 09 27.
Article em En | MEDLINE | ID: mdl-36097964
The point-of-care (POC) method with affordability and portability for the sensitive detection of biological substances is an emerging topic in rapid disease screening and personalized medicine. In this work, we demonstrated a diverse responsive platform based on a dual-channel pressure sensor (DCPS). The DCPS had a multilayer flexible architecture consisting of a photonic hydrogel with chromatic transitions and a piezoresistive pressure sensor as the electrical data transmission unit, both of which had the property of pressure-induced mechanical stimulus feedback. By incorporating a platinum nanoparticles-labeled detection antibody (PtNPs-dAb) into the sandwich-type immunoreaction for the target carcinoembryonic antigen (CEA, as a model analyte), gas decomposition could be triggered by the addition of hydrogen peroxide (H2O2) to induce a significant increase under pressure in a closed chamber. Meanwhile, the DCPS enabled an accurate electrical signal output, and the photonic hydrogel converted spatiotemporal stimuli into eye-readable colorations with string brilliance. In this way, the target concentration could be quantificationally related to the electrical response and intuitively perceived through visible color alterations. Under optimal conditions, a sensitive determination of CEA was performed in a detectable range of 0.3-60 ng/mL with a limit of detection (LOD) of 0.13 ng/mL. In addition, the proposed protocol had satisfactory selectivity, accuracy, and reproducibility. Furthermore, an array-based immunoassay device was fabricated to conceptually validate its application potential in high-throughput biomedical detection and inspire a dual-signal POC diagnostic platform in a friendly way for resource-limited settings.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas Tipo de estudo: Guideline / Prognostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas Metálicas Tipo de estudo: Guideline / Prognostic_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article