Between-devices agreement in obtaining raw bioelectrical parameters after a lifestyle intervention targeting weight loss in former athletes.
Silva, Tiago R; Nunes, Catarina L; Jesus, Filipe; Francisco, Ruben; Teixeira, Vitor H; Sardinha, Luis B; Martins, Paulo; Minderico, Cláudia; Silva, Analiza M.
Afiliação
  • Silva TR; Faculty of Nutrition and Food Sciences, University of Porto, Porto, Portugal.
  • Nunes CL; Exercise and Health Laboratory, CIPER, Faculty of Human Kinetics, University of Lisbon, Cruz-Quebrada, Portugal.
  • Jesus F; Exercise and Health Laboratory, CIPER, Faculty of Human Kinetics, University of Lisbon, Cruz-Quebrada, Portugal.
  • Francisco R; Exercise and Health Laboratory, CIPER, Faculty of Human Kinetics, University of Lisbon, Cruz-Quebrada, Portugal.
  • Teixeira VH; Faculty of Nutrition and Food Sciences, University of Porto, Porto, Portugal.
  • Sardinha LB; Research Centre in Physical Activity, Health and Leisure (CIAFEL), Faculty of Sports, University of Porto, Porto, Portugal.
  • Martins P; Laboratory for Integrative and Translational Research in Population Health (ITR), University of Porto, Porto, Portugal.
  • Minderico C; Exercise and Health Laboratory, CIPER, Faculty of Human Kinetics, University of Lisbon, Cruz-Quebrada, Portugal.
  • Silva AM; Exercise and Health Laboratory, CIPER, Faculty of Human Kinetics, University of Lisbon, Cruz-Quebrada, Portugal.
J Sports Sci ; 40(16): 1857-1864, 2022 Aug.
Article em En | MEDLINE | ID: mdl-36101017
It is unclear if different bioelectrical impedance (BI) devices provide similar results regarding raw parameters [Resistance (R), Reactance (Xc), Phase Angle (PhA), and Impedance (Z)] for the same population/individual undergoing a weight loss intervention. The aim was to evaluate the cross-sectional and longitudinal agreement of raw data obtained by two BI devices in former athletes with overweight/obesity. Fifty-nine participants [mean (SD): 43.5 (9.2) years, 30.5 (4.0) kg/m2, 42% females] were included. All the assessments were performed before and after a 4-months lifestyle intervention targeting weight loss (WL). BI parameters were assessed at 50 kHz by two devices: a BI spectroscopy (Xitron Technologies, 4200B, San Diego, USA) and a phase-sensitive single-frequency device (BIA 101 AKERN, Florence, Italy). Cross-sectionally, BIS provided lower mean values for all parameters (0.4% for R, 1.6% for Xc, 1.0% for PhA and 0.4% for Z, p <0.001) compared to SF-BIA. In individuals with a WL≥2.5% (n =18), no longitudinal differences were found in any of the raw parameters between devices (p≥0.128) and there was no proportional bias (p≥0.408). Despite small baseline differences in raw BI parameters, both devices agreed in tracking changes over time at the group level but interpretation should be careful at the individual level.