Your browser doesn't support javascript.
loading
An electrochemical aptasensor based on target triggered multiple-channel DNAzymes cycling amplification strategy with PtFe@Co-MOF as signal amplifier.
Zhu, Tong; Li, Na; Huang, Jiangjian; Xu, Xiaohansi; Su, Xin; Ma, Yi; Yang, Renxiang; Ruan, Jia; Su, Huilan.
Afiliação
  • Zhu T; School of Public Health, Chengdu Medical College, Chengdu, 610050, China.
  • Li N; School of Public Health, Chengdu Medical College, Chengdu, 610050, China.
  • Huang J; School of Public Health, Chengdu Medical College, Chengdu, 610050, China.
  • Xu X; School of Public Health, Chengdu Medical College, Chengdu, 610050, China.
  • Su X; School of Public Health, Chengdu Medical College, Chengdu, 610050, China.
  • Ma Y; School of Public Health, Chengdu Medical College, Chengdu, 610050, China.
  • Yang R; School of Public Health, Chengdu Medical College, Chengdu, 610050, China.
  • Ruan J; School of Public Health, Chengdu Medical College, Chengdu, 610050, China. 1041819360@qq.com.
  • Su H; School of Public Health, Chengdu Medical College, Chengdu, 610050, China. suhuilan@vip.163.com.
Mikrochim Acta ; 189(10): 388, 2022 09 21.
Article em En | MEDLINE | ID: mdl-36129574
ABSTRACT
A novel electrochemical aptasensor for the detection of Aflatoxin B1 (AFB1) was developed for the first time by using the target-triggered multiple-channel deoxyribozymes (DNAzymes) cycling amplified assay with Pt Fe doped NH2-Co-MOF (PtFe@Co-MOF) as a signal amplifier. In the presence of AFB1, a self-assembling cross-over nucleic structure could be triggered by AFB1 via two aptamers' structure switching for strand displacement, resulting in four channels of Mg2+-dependent DNAzyme recycling simultaneously to multiply the detection signals. These DNAzymes cyclically split the substrate sequence to release the PtFe@Co-MOF labeled detection probe (DP), which is subsequently hybridized with the capture probes on the Au-deposited glassy carbon electrode. The fabrication procedure was characterized by differential pulse voltammetry, and the results of the morphological and element composition characteristics methods were analyzed to determine the successful preparation of PtFe@Co-MOF. The limit of detection (LOD) for AFB1 detection was 2 pg mL-1 with a linear range from 5 pg mL-1 to 80 ng mL-1. By comparison, the enhanced detection sensitivity has been found to originate from the efficient shearing of DNAzymes, enhanced peroxidase-like capability, and multiple active sites of PtFe@Co-MOF. Besides, this aptasensor showed high specificity for AFB1 compared with similar mycotoxins and exhibited high accuracy with low experimental cost and easy operation. Furthermore, the unique design of electrochemical aptasensors could provide a promising platform for the onsite determination of AFB1, as well as other targets by replacing the aptamer and other core recognition sequences.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / DNA Catalítico / Aptâmeros de Nucleotídeos Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / DNA Catalítico / Aptâmeros de Nucleotídeos Idioma: En Ano de publicação: 2022 Tipo de documento: Article