Assessing the Impacts of Preanalytical Field Sampling Challenges on the Reliability of Serum Aflatoxin B1-Lysine Measurements by Use of LC-MS/MS.
Zitomer, Nicholas C; Rybak, Michael E; Sternberg, Maya R.
Afiliação
  • Zitomer NC; Nutritional Biomarkers Branch, Division of Laboratory Sciences, National Center for Environmental Health, US Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
  • Rybak ME; Nutritional Biomarkers Branch, Division of Laboratory Sciences, National Center for Environmental Health, US Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
  • Sternberg MR; Nutritional Biomarkers Branch, Division of Laboratory Sciences, National Center for Environmental Health, US Centers for Disease Control and Prevention, Atlanta, GA 30341, USA.
Toxins (Basel) ; 14(9)2022 09 01.
Article em En | MEDLINE | ID: mdl-36136549
Aflatoxin exposure is endemic in developing countries with warm, humid climates that promote toxigenic mold growth on crops and foodstuffs. Estimating human aflatoxin exposure is key to identifying and abating contamination sources. Serum aflatoxin B1 bound to albumin lysine (AFB1-lys) is a preferred exposure biomarker, but field sample collection, processing, transportation, and storage logistics are challenging. We validated an improved LC-MS/MS method for serum AFB1-lys and applied it to three field sampling challenges: transportation/storage (elevated temperature); collection/processing (hemolysis); and sample type substitution (heparinized plasma). Our new LC-MS/MS method had a LOD of 0.03 ng/mL, accuracy (mean spike recovery) of 112%, total imprecision (replicate pool measurements) ≤5% at ≥0.2 ng/mL, and results that were 95.1% similar (mean percentage similarity) to an established method. AFB1-lys in human serum spiked with serum from aflatoxin-dosed rats was stable for 14 days at both ambient (22.5 °C) and elevated (38 °C) temperatures. Simulated hemolysis (adding 0.25-3 mg hemoglobin) did not affect AFB1-lys accuracy at ≥0.5 ng/mL but caused 10-25% signal suppression. Heparinized plasma AFB1-lys was 99.0% similar to serum but interfered with albumin measurements (bromocresol green) causing spurious low bias. Further investigation is warranted, but our findings suggest that AFB1-lys is pre-analytically robust.