Your browser doesn't support javascript.
loading
Evaluation of fully automated commercial software for Agatston calcium scoring on non-ECG-gated low-dose chest CT with different slice thickness.
Kang, Hyun Woo; Ahn, Woo Jin; Jeong, Ju Hyun; Suh, Young Joo; Yang, Dong Hyun; Choi, Hangseok; Hwang, Sung Ho; Yong, Hwan Seok; Oh, Yu-Whan; Kang, Eun-Young; Kim, Cherry.
Afiliação
  • Kang HW; Korea University College of Medicine, Seoul, South Korea.
  • Ahn WJ; Korea University College of Medicine, Seoul, South Korea.
  • Jeong JH; Department of Radiology, Ansan Hospital, Korea University College of Medicine, 123, Jeokgeum-ro, Danwon-gu, Ansan-si, Gyeonggi-do, South Korea.
  • Suh YJ; Department of Radiology, Severance Hospital, Research Institute of Radiological Science, Center for Clinical Imaging Data Science, Yonsei University College of Medicine, Seoul, South Korea.
  • Yang DH; Department of Radiology and Research Institute of Radiology, Cardiac Imaging Center, Asan Medical Center, University of Ulsan College of Medicine, Seoul, South Korea.
  • Choi H; Medical Science Research Center, Korea University College of Medicine, Seoul, South Korea.
  • Hwang SH; Department of Radiology, Anam Hospital, Korea University College of Medicine, 73, Goryeodae-ro, Seongbuk-gu, Seoul, 02841, South Korea.
  • Yong HS; Department of Radiology, Guro Hospital, Korea University College of Medicine, 148, Gurodong-ro, Guro-gu, Seoul, 08308, South Korea.
  • Oh YW; Department of Radiology, Anam Hospital, Korea University College of Medicine, 73, Goryeodae-ro, Seongbuk-gu, Seoul, 02841, South Korea.
  • Kang EY; Department of Radiology, Guro Hospital, Korea University College of Medicine, 148, Gurodong-ro, Guro-gu, Seoul, 08308, South Korea.
  • Kim C; Department of Radiology, Ansan Hospital, Korea University College of Medicine, 123, Jeokgeum-ro, Danwon-gu, Ansan-si, Gyeonggi-do, South Korea. cherrykim0505@gmail.com.
Eur Radiol ; 33(3): 1973-1981, 2023 Mar.
Article em En | MEDLINE | ID: mdl-36152039
ABSTRACT

OBJECTIVES:

To evaluate commercial deep learning-based software for fully automated coronary artery calcium (CAC) scoring on non-electrocardiogram (ECG)-gated low-dose CT (LDCT) with different slice thicknesses compared with manual ECG-gated calcium-scoring CT (CSCT).

METHODS:

This retrospective study included 567 patients who underwent both LDCT and CSCT. All LDCT images were reconstructed with a 2.5-mm slice thickness (LDCT2.5-mm), and 453 LDCT scans were reconstructed with a 1.0-mm slice thickness (LDCT1.0-mm). Automated CAC scoring was performed on CSCT (CSCTauto), LDCT1.0-mm, and LDCT2.5-mm images. The reliability of CSCTauto, LDCT1.0-mm, and LDCT2.5-mm was compared with manual CSCT scoring (CSCTmanual) using intraclass correlation coefficients (ICCs) and Bland-Altman analysis. Agreement, in CAC severity category, was analyzed using weighted kappa statistics. Diagnostic performance at various Agatston score cutoffs was also calculated.

RESULTS:

CSCTauto, LDCT1.0-mm, and LDCT2.5-mm demonstrated excellent agreement with CSCTmanual (ICC [95% confidence interval, CI] 1.000 [1.000, 1.000], 0.937 [0.917, 0.952], and 0.955 [0.946, 0.963], respectively). The mean difference with 95% limits of agreement was lower with LDCT1.0-mm than with LDCT2.5-mm (19.94 [95% CI, -244.0, 283.9] vs. 45.26 [-248.2, 338.7]). Regarding CAC severity, LDCT1.0-mm achieved almost perfect agreement, and LDCT2.5-mm achieved substantial agreement (kappa [95% CI] 0.809 [0.776, 0.838], 0.776 [0.740, 0.809], respectively). Diagnostic performance for detecting Agatston score ≥ 400 was also higher with LDCT1.0-mm than with LDCT2.5-mm (F1 score, 0.929 vs. 0.855).

CONCLUSIONS:

Fully automated CAC-scoring software with both CSCT and LDCT yielded excellent reliability and agreement with CSCTmanual. LDCT1.0-mm yielded more accurate Agatston scoring than LDCT2.5-mm using fully automated commercial software. KEY POINTS • Total Agatston scores and all vessels of CSCTauto, LDCT1.0-mm, and LDCT2.5-mm demonstrated excellent agreement with CSCTmanual (all ICC > 0.85). • The diagnostic performance for detecting all Agatston score cutoffs was better with LDCT1.0-mm than with LDCT2.5-mm. • This automated software yielded a lower degree of underestimation compared with methods described in previous studies, and the degree of underestimation was lower with LDCT1.0-mm than with LDCT2.5-mm.