Your browser doesn't support javascript.
loading
Assessing component orientation of total hip arthroplasty using the low-dose bi-planar radiographs.
Ma, Zhuyi; Tang, Hao; Zhou, Yixin; Wang, Siyuan; Yang, Dejin; Guo, Shaoyi.
Afiliação
  • Ma Z; Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, No.31 Xinjiekou East Street, Xicheng District, Beijing, China.
  • Tang H; Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, No.31 Xinjiekou East Street, Xicheng District, Beijing, China.
  • Zhou Y; Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, No.31 Xinjiekou East Street, Xicheng District, Beijing, China. orthoyixin@yahoo.com.
  • Wang S; Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, No.31 Xinjiekou East Street, Xicheng District, Beijing, China.
  • Yang D; Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, No.31 Xinjiekou East Street, Xicheng District, Beijing, China.
  • Guo S; Department of Orthopaedics, Beijing Jishuitan Hospital, Fourth Clinical College of Peking University, No.31 Xinjiekou East Street, Xicheng District, Beijing, China.
BMC Musculoskelet Disord ; 23(1): 886, 2022 Sep 26.
Article em En | MEDLINE | ID: mdl-36154920
BACKGROUND: Three-dimensional computed tomography (3D CT) reconstruction is the reference standard for measuring component orientation. However, functional cup orientation in standing position is preferable compared with supine position. The low-dose bi-planar radiographs can be used to analyze standing cup component orientation. We aimed to assess the validity and reliability of the component orientation using the low-dose bi-planar radiographs compared with the 3D CT reconstruction, and explore the differences between the functional cup orientation in standing radiographs and supine CT scans. METHODS: A retrospective study, including 44 patients (50 hips) with total hip arthroplasty (THA), was conducted. CT scans were taken 1 week after surgery and the low-dose bi-planar radiographs were taken in the follow-up 6 weeks later. Component orientation measurement was performed using the anterior pelvic plane and the radiographic coronal plane as reference, respectively. RESULTS: The study showed no significant difference in cup anteversion (p = 0.160), cup inclination (p = 0.486), and stem anteversion (p = 0.219) measured by the low-dose bi-planar radiographs and 3D reconstruction. The differences calculated by the Bland-Altman analysis ranged from - 0.4° to 0.6° for the three measured angles. However, the mean absolute error was 4.76 ± 1.07° for functional anteversion (p = 0.035) and 4.02 ± 1.08° for functional inclination (p = 0.030) measured by the bi-planar radiographs and supine CT scans. CONCLUSIONS: The low-dose bi-planar radiographs are the same reliable and accurate as 3D CT reconstruction to assess post-THA patients' component orientation, while providing more valuable functional component orientation than supine CT scans.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Prótese de Quadril Tipo de estudo: Observational_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Artroplastia de Quadril / Prótese de Quadril Tipo de estudo: Observational_studies Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article