Your browser doesn't support javascript.
loading
Utilization of a Novel Immunofluorescence Instrument Prototype for the Determination of the Herbicide Glyphosate.
Takács, Eszter; Gémes, Borbála; Szendrei, Fanni; Keszei, Csaba; Barócsi, Attila; Lenk, Sándor; Domján, László; Mörtl, Mária; Székács, András.
Afiliação
  • Takács E; Agro-Environmental Research Centre, Institute of Environmental Sciences, Hungarian University of Agriculture and Life Sciences, Herman O. út 15, H-1022 Budapest, Hungary.
  • Gémes B; Agro-Environmental Research Centre, Institute of Environmental Sciences, Hungarian University of Agriculture and Life Sciences, Herman O. út 15, H-1022 Budapest, Hungary.
  • Szendrei F; Institute of Isotopes Co. Ltd., Konkoly-Thege Miklós út 29-33, H-1121 Budapest, Hungary.
  • Keszei C; Institute of Isotopes Co. Ltd., Konkoly-Thege Miklós út 29-33, H-1121 Budapest, Hungary.
  • Barócsi A; Department of Atomic Physics, Institute of Physics, Budapest University of Technology and Economics, Muegyetem rkp. 3, H-1111 Budapest, Hungary.
  • Lenk S; Department of Atomic Physics, Institute of Physics, Budapest University of Technology and Economics, Muegyetem rkp. 3, H-1111 Budapest, Hungary.
  • Domján L; Optimal Optik Ltd., Dayka Gábor u. 6/B, H-1118 Budapest, Hungary.
  • Mörtl M; Agro-Environmental Research Centre, Institute of Environmental Sciences, Hungarian University of Agriculture and Life Sciences, Herman O. út 15, H-1022 Budapest, Hungary.
  • Székács A; Agro-Environmental Research Centre, Institute of Environmental Sciences, Hungarian University of Agriculture and Life Sciences, Herman O. út 15, H-1022 Budapest, Hungary.
Molecules ; 27(19)2022 Oct 02.
Article em En | MEDLINE | ID: mdl-36235051
ABSTRACT
An enzyme-linked fluorescent immunoassay (ELFIA) method has been developed for the quantitative analytical determination of the herbicide active ingredient glyphosate in environmental matrices (surface water, soil, and plant tissues). Glyphosate, as a ubiquitous agricultural pollutant, is a xenobiotic substance with exposure in aquatic and terrestrial ecosystems due its extremely high worldwide application rate. The immunoassay developed in Project Aquafluosense is part of a fluorescence-based instrumentation setup for the in situ determination of several characteristic water quality parameters. The 96-well microplate-based competitive immunoassay method applies fluorescence signal detection in the concentration range of 0-100 ng/mL glyphosate. Application of the fluorescent signal provides a limit of detection of 0.09 ng/mL, which is 2.5-fold lower than that obtained with a visual absorbance signal. Beside the improved limit of detection, determination by fluorescence provided a wider and steeper dynamic range for glyphosate detection. No matrix effect appeared for the undiluted surface water samples, while plant tissues and soil samples required dilution rates of 110 and 1100, respectively. No cross-reaction was determined with the main metabolite of glyphosate, N-aminomethylphosphonic acid, and related compounds.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Ambientais / Herbicidas Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Ambientais / Herbicidas Idioma: En Ano de publicação: 2022 Tipo de documento: Article