Your browser doesn't support javascript.
loading
Spatiotemporally Resolved pH Measurement in Aerosol Microdroplets Undergoing Chloride Depletion: An Application of In Situ Raman Microspectrometry.
Jing, Xinbo; Chen, Zhe; Huang, Qishen; Liu, Pai; Zhang, Yun-Hong.
Afiliação
  • Jing X; Institute of Chemical Physics, School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing100081, China.
  • Chen Z; Institute of Chemical Physics, School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing100081, China.
  • Huang Q; Institute of Chemical Physics, School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing100081, China.
  • Liu P; Department of Chemistry, The Pennsylvania State University, University Park, Pennsylvania16801, United States.
  • Zhang YH; Institute of Chemical Physics, School of Chemistry and Chemical Engineering, Beijing Institute of Technology, Beijing100081, China.
Anal Chem ; 94(43): 15132-15138, 2022 11 01.
Article em En | MEDLINE | ID: mdl-36251492
ABSTRACT
Acidity is a defining property of atmospheric aerosols that profoundly affects environmental systems, human health, and climate. However, directly measuring the pH of aerosol microdroplets remains a challenge, especially when the microdroplets' composition is nonhomogeneous or dynamically evolving or both. As a result, a pH measurement technique with high spatiotemporal resolution is needed. Here, we report a spatiotemporally resolved pH measurement technique in microdroplets using spontaneous Raman spectroscopy. Our target sample was the microdroplets comprising sodium chloride and oxalic acid─laboratory surrogates of sea spray aerosols and water-soluble organic compounds, respectively. Our measurements show that the chloride depletion from the microdroplets caused a continuous increase in pH by ∼0.5 units in 2 hours. Meanwhile, the surface propensity of chloride anions triggers a stable pH gradient inside a single droplet, with the pH at the droplet surface lower than that at the core by ∼ 0.4 units. The uncertainties arising from the Raman detection limit (±0.08 pH units) and from the nonideal solution conditions (-0.06 pH units) are constrained. Our findings indicate that spontaneous Raman spectroscopy is a simple yet robust technique for precise pH measurement in aerosols with high spatiotemporal resolution.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise Espectral Raman / Cloretos Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Análise Espectral Raman / Cloretos Limite: Humans Idioma: En Ano de publicação: 2022 Tipo de documento: Article