Reliability of Frankfort Horizontal Plane with True Horizontal Plane in Cephalometric Measurements.
Devi, S Sowmithra; Dinesh, Saravana; Sivakumar, Arvind; Nivethigaa, B; Alshehri, Abdulrahman; Awadh, Wael; Alam, Mohammad Khursheed; Bhandi, Shilpa; Raj, A Thirumal; Patil, Shankargouda.
Afiliação
  • Devi SS; Department of Orthodontics and Dentofacial Orthopedics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Chennai, Tamil Nadu, India, Phone: +91 6380813983, e-mail: sowmithrasaravanan@gmail.com.
  • Dinesh S; Department of Orthodontics and Dentofacial Orthopedics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Chennai, Tamil Nadu, India.
  • Sivakumar A; Department of Orthodontics and Dentofacial Orthopedics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Chennai, Tamil Nadu, India.
  • Nivethigaa B; Department of Orthodontics and Dentofacial Orthopedics, Saveetha Dental College and Hospitals, Saveetha Institute of Medical and Technical Sciences, Chennai, Tamil Nadu, India.
  • Alshehri A; Department of Preventive Dental Sciences, Division of Orthodontics, College of Dentistry, Jazan University, Jazan, Saudi Arabia.
  • Awadh W; Department of Preventive Dental Sciences, Division of Orthodontics, College of Dentistry, Jazan University, Jazan, Saudi Arabia.
  • Alam MK; Department of Orthodontics and Preventive Dentistry, College of Dentistry, Jouf University, Sakaka, Saudi Arabia; Center for Transdisciplinary Research, Saveetha Dental College, Saveetha Institute of Medical and Technical Sciences, Saveetha University, Chennai, Tamil Nadu, India; Department of Publi
  • Bhandi S; Department of Restorative Dental Science, Division of Operative Dentistry, College of Dentistry, Jazan University, Jazan, Saudi Arabia.
  • Raj AT; Department of Oral Pathology and Microbiology, Sri Venkateswara Dental College and Hospital, Chennai, Tamil Nadu, India.
  • Patil S; Department of Maxillofacial Surgery and Diagnostic Sciences, Division of Oral Pathology, College of Dentistry, Jazan University, Jazan, Saudi Arabia, Phone: +966507633755, e-mail: dr.ravipatil@gmail.com.
J Contemp Dent Pract ; 23(6): 601-605, 2022 Sep 23.
Article em En | MEDLINE | ID: mdl-36259298
ABSTRACT

INTRODUCTION:

The purpose of the study is to determine reliability of true horizontal (TH) plane with Frankfort horizontal (FH) plane in cephalometric measurements. MATERIALS AND

METHODS:

One hundred lateral cephalograms were collected and traced using FACAD software, all cephalometric measurements which included FH plane as reference planes were used in this study. Cephalometric tracing was done with FH plane as reference plane and another set of measurements with TH plane as reference plane was done. Statistical tests were done using independent sample t-test (p <0.05).

RESULTS:

Results of an independent t-test revealed a statistically insignificant difference that was observed for all the parameters assessed (p <0.05). Both angular and linear measurements showed an insignificant difference between FH and TH.

CONCLUSION:

Within the limitations of the study, the results show that the FH plane is closest and as reliable as the TH plane. The variation of FH was least for all the parameters assessed.