Your browser doesn't support javascript.
loading
Refractive outcomes and optical quality of PRESBYOND laser-blended vision for presbyopia correction.
Fu, Dan; Aruma, Aruma; Xu, Ye; Han, Tian; Xia, Fei; Zhou, Xing-Tao.
Afiliação
  • Fu D; Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai 200030, China.
  • Aruma A; NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai 200031, China.
  • Xu Y; Shanghai Research Center of Ophthalmology and Optometry, Shanghai 200031, China.
  • Han T; Shanghai Engineering Research Center of Laser and Autostereoscopic 3D for Vision Care, Shanghai 200031, China.
  • Xia F; Eye Institute and Department of Ophthalmology, Eye & ENT Hospital, Fudan University, Shanghai 200030, China.
  • Zhou XT; NHC Key Laboratory of Myopia (Fudan University); Key Laboratory of Myopia, Chinese Academy of Medical Sciences, Shanghai 200031, China.
Int J Ophthalmol ; 15(10): 1671-1675, 2022.
Article em En | MEDLINE | ID: mdl-36262841
ABSTRACT

AIM:

To investigate the one-year refractive outcomes and optical quality following PRESBYOND laser-blended vision (LBV).

METHODS:

This retrospective study included 20 patients who underwent PRESBYOND treatment between Jan 2019 and Aug 2020. The patients were asked to attend a follow-up outpatient visit one year after surgery. Distance and near visual acuity as well as subjective refraction were examined. Optical quality was assessed using wavefront-supported custom ablation. A questionnaire evaluating optical quality and satisfaction was completed at the last visit.

RESULTS:

The average patient age was 48.1±7.4y (range, 41 to 58y). The mean preoperative spherical equivalent was -7.59±2.39 D. At the one-year follow-up, two eyes (both dominant eyes) lost one line of corrected distance visual acuity (CDVA), while the remaining eyes (38/40) maintained or gained lines of CDVA. The average binocular uncorrected distance visual acuity improved from 0.15±0.03 to 0.90±0.26 (decimal vision; P<0.001). The average binocular uncorrected near visual acuity increased from 0.34±0.28 to 0.97±0.07 (P<0.001). The spherical aberration was 0.04±0.06 µm in the nondominant eye and 0.09±0.09 µm in the dominant eye (P=0.02). All patients were satisfied with or accepted the outcomes of the surgery. The primary complaints were related to disturbances in night vision and relatively inferior near vision.

CONCLUSION:

Over the one-year observation period, PRESBYOND is a safe and effective option for presbyopia correction. The optical quality and near vision deserve further investigation.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Observational_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Observational_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article