Your browser doesn't support javascript.
loading
General Label-Free Fluorescent Aptamer Binding Assay Using Cationic Conjugated Polymers.
Zhang, Pengbo; Qin, Ke; Lopez, Anand; Li, Zhengping; Liu, Juewen.
Afiliação
  • Zhang P; School of Chemistry and Biological Engineering, University of Science and Technology Beijing, 30 Xueyuan Road, Haidian District, Beijing 100083, China.
  • Qin K; Department of Chemistry, Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
  • Lopez A; School of Chemistry and Biological Engineering, University of Science and Technology Beijing, 30 Xueyuan Road, Haidian District, Beijing 100083, China.
  • Li Z; Department of Chemistry, Waterloo Institute for Nanotechnology, University of Waterloo, 200 University Avenue West, Waterloo, Ontario N2L 3G1, Canada.
  • Liu J; School of Chemistry and Biological Engineering, University of Science and Technology Beijing, 30 Xueyuan Road, Haidian District, Beijing 100083, China.
Anal Chem ; 94(44): 15456-15463, 2022 11 08.
Article em En | MEDLINE | ID: mdl-36282236
ABSTRACT
With more and more new aptamers being reported, a general, cost-effective yet reliable aptamer binding assay is still needed. Herein, we studied cationic conjugated polymer (CCP)-based binding assays taking advantage of the conformational change of aptamer after binding with a target, which is reflected by the fluorescence change of the CCP. Poly(3-(3'-N,N,N-triethylamino-1'-propyloxy)-4-methyl-2,5-thiophene hydrochloride) (PMNT) was used as a model CCP in this study, and the optimal buffer was close to physiological conditions with 100 mM NaCl and 10 mM MgCl2. We characterized four aptamers for K+, adenosine, cortisol, and caffeine. For cortisol and caffeine, the drop in the 580 nm peak intensity was used for quantification, whereas for K+ and adenosine, the fluorescence ratio at 580 over 530 nm was used. The longer stem of the stem-loop structured aptamer facilitated binding of the target and enlarged the detection signal. High specificity was achieved in differentiating targets with analogues. Compared with the SYBR Green I dye-based staining method, our method achieved equal or even higher sensitivity. Therefore, this assay is practicable as a general aptamer binding assay. The simple, label-free, quick response, and cost-effective features will make it a useful method to evaluate aptamer binding. At the same time, this system can also serve as label-free biosensors for target detection.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Aptâmeros de Nucleotídeos Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Aptâmeros de Nucleotídeos Idioma: En Ano de publicação: 2022 Tipo de documento: Article