Your browser doesn't support javascript.
loading
Artificial intelligence augments detection accuracy of cardiac insertable cardiac monitors: Results from a pilot prospective observational study.
Quartieri, Fabio; Marina-Breysse, Manuel; Pollastrelli, Annalisa; Paini, Isabella; Lizcano, Carlos; Lillo-Castellano, José María; Grammatico, Andrea.
Afiliação
  • Quartieri F; Department of Cardiology, Azienda Ospedaliera S. Maria Nuova, Reggio Emilia, Italy.
  • Marina-Breysse M; IDOVEN Research, AI Team, Madrid, Spain.
  • Pollastrelli A; Advanced Development in Arrhythmia Mechanisms and Therapy Laboratory, Myocardial Pathophysiology Area, Centro Nacional de Investigaciones Cardiovasculares (CNIC), Madrid, Spain.
  • Paini I; Centro de Investigación Biomédica en Red de Enfermedades Cardiovasculares (CIBERCV), Madrid, Spain.
  • Lizcano C; EMEA CRM Medical Affairs, Abbott, Rome, Italy.
  • Lillo-Castellano JM; Department of Cardiology, Azienda Ospedaliera S. Maria Nuova, Reggio Emilia, Italy.
  • Grammatico A; IDOVEN Research, AI Team, Madrid, Spain.
Cardiovasc Digit Health J ; 3(5): 201-211, 2022 Oct.
Article em En | MEDLINE | ID: mdl-36310681
Background: Insertable cardiac monitors (ICMs) are indicated for long-term monitoring of patients with unexplained syncope or who are at risk for cardiac arrhythmias. The volume of ICM-transmitted information may result in long data review times to identify true and clinically relevant arrhythmias. Objective: The purpose of this study was to evaluate whether artificial intelligence (AI) may improve ICM detection accuracy. Methods: We performed a retrospective analysis of consecutive patients implanted with the Confirm RxTM ICM (Abbott) and followed in a prospective observational study. This device continuously monitors subcutaneous electrocardiograms (SECGs) and transmits to clinicians information about detected arrhythmias and patient-activated symptomatic episodes. All SECGs were classified by expert electrophysiologists and by the WillemTM AI algorithm (IDOVEN). Results: During mean follow-up of 23 months, of 20 ICM patients (mean age 68 ± 12 years; 50% women), 19 had 2261 SECGs recordings associated with cardiac arrhythmia detections or patient symptoms. True arrhythmias occurred in 11 patients: asystoles in 2, bradycardias in 3, ventricular tachycardias in 4, and atrial tachyarrhythmias (atrial tachycardia/atrial fibrillation [AT/AF]) in 10; with 6 patients having >1 arrhythmia type. AI algorithm overall accuracy for arrhythmia classification was 95.4%, with 97.19% sensitivity, 94.52% specificity, 89.74% positive predictive value, and 98.55% negative predictive value. Application of AI would have reduced the number of false-positive results by 98.0% overall: 94.0% for AT/AF, 87.5% for ventricular tachycardia, 99.5% for bradycardia, and 98.8% for asystole. Conclusion: Application of AI to ICM-detected episodes is associated with high classification accuracy and may significantly reduce health care staff workload by triaging ICM data.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Tipo de estudo: Diagnostic_studies / Observational_studies / Prognostic_studies / Risk_factors_studies Idioma: En Ano de publicação: 2022 Tipo de documento: Article