Your browser doesn't support javascript.
loading
Ultrasonic Evaluation of the Heel Fat Pad Under Loading Conditions Using a Polymethylpentene Resin Plate: Part 2. Reliability and Agreement Study.
Matsumoto, Masatomo; Maemichi, Toshihiro; Wada, Mitsunari; Niwa, Yuki; Inagaki, Shinobu; Taguchi, Atsuya; Okunuki, Takumi; Tanaka, Hirofumi; Kumai, Tsukasa.
Afiliação
  • Matsumoto M; Graduate School of Sport Sciences, Waseda University, Tokorozawa, Saitama, Japan; Department of Medical Rehabilitation, Kuwana City Medical Center, Kuwana City, Mie, Japan. Electronic address: mmtomochan@moegi.waseda.jp.
  • Maemichi T; Faculty of Sport Sciences, Waseda University, Tokorozawa, Saitama, Japan.
  • Wada M; Department of Medical Rehabilitation, Kuwana City Medical Center, Kuwana City, Mie, Japan.
  • Niwa Y; Department of Medical Rehabilitation, Kuwana City Medical Center, Kuwana City, Mie, Japan.
  • Inagaki S; Department of Medical Rehabilitation, Kuwana City Medical Center, Kuwana City, Mie, Japan.
  • Taguchi A; Department of Medical Rehabilitation, Kuwana City Medical Center, Kuwana City, Mie, Japan.
  • Okunuki T; Graduate School of Sport Sciences, Waseda University, Tokorozawa, Saitama, Japan; Research Fellow of Japan Society for the Promotion of Science, Chiyoda-ku, Tokyo, Japan.
  • Tanaka H; Graduate School of Sport Sciences, Waseda University, Tokorozawa, Saitama, Japan; Hyakutake Orthopedic & Sports Clinic, Saga City, Saga, Japan.
  • Kumai T; Faculty of Sport Sciences, Waseda University, Tokorozawa, Saitama, Japan.
Ultrasound Med Biol ; 49(2): 460-472, 2023 02.
Article em En | MEDLINE | ID: mdl-36335054
ABSTRACT
Previously, we developed an instrument to evaluate the heel fat pad (HFP) two-layer structure, under varying loading conditions, with ultrasonography from the plantar surface through a polymethylpentene resin plate; the measured values were equivalent to those obtained without this plate. The study described here aimed to determine the intra- and inter-examiner reliabilities of the HFP thickness measurements and the agreement between long- and short-axis measured values using this instrument. Two examiners successively recorded the HFPs of 40 healthy adults twice under the no loading and loading conditions on the long- and short-axis scans. The HFPs were classified into two layers, and their thicknesses were measured. Short-term intra- and inter-examiner reliabilities were determined using the intraclass correlation coefficients. Measurements were repeated 1 mo later to determine the long-term intra-examiner reliability. The agreement between the measured long- and short-axis values was investigated by calculating the minimal detectable changes. The determined short- and long-term intra-examiner reliabilities ranged from 0.750 to 0.999 and from 0.765 to 0.952, respectively. Inter-examiner reliability ranged from 0.765 to 0.997. Differences may occur between the values measured at different axes. The measurements using this evaluation instrument were reliable, and it is best to unify the measurement axis for quantitative research.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ultrassom / Calcanhar Limite: Adult / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Ultrassom / Calcanhar Limite: Adult / Humans Idioma: En Ano de publicação: 2023 Tipo de documento: Article