A Sensitive and Selective Colorimetric Method Based on the Acetylcholinesterase-like Activity of Zeolitic Imidazolate Framework-8 and Its Applications.
Chen, Guo-Ying; Qian, Zheng-Ming; Yin, Shi-Jun; Zhou, Xi; Yang, Feng-Qing.
Afiliação
  • Chen GY; School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China.
  • Qian ZM; College of Medical Imagine Laboratory and Rehabilitation, Xiangnan University, Chenzhou 423000, China.
  • Yin SJ; Dongguan HEC Cordyceps R&D Co., Ltd., Dongguan 523850, China.
  • Zhou X; School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China.
  • Yang FQ; School of Chemistry and Chemical Engineering, Chongqing University, Chongqing 401331, China.
Molecules ; 27(21)2022 Nov 03.
Article em En | MEDLINE | ID: mdl-36364318
ABSTRACT
In this study, a simple colorimetric method was established to detect copper ion (Cu2+), sulfathiazole (ST), and glucose based on the acetylcholinesterase (AChE)-like activity of zeolitic imidazolate framework-8 (ZIF-8). The AChE-like activity of ZIF-8 can hydrolyze acetylthiocholine chloride (ATCh) to thiocholine (TCh), which will further react with 5,5'-dithiobis (2-nitrobenzoic acid) (DTNB) to generate 2-nitro-5-thiobenzoic acid (TNB) that has a maximum absorption peak at 405 nm. The effects of different reaction conditions (buffer pH, the volume of ZIF-8, reaction temperature and time, and ATCh concentration) were investigated. Under the optimized conditions, the value of the Michaelis-Menten constant (Km) is measured to be 0.83 mM, which shows a high affinity toward the substrate (ATCh). Meanwhile, the ZIF-8 has good storage stability, which can maintain more than 80.0% of its initial activity after 30 days of storage at room temperature, and the relative standard deviation (RSD) of batch-to-batch (n = 3) is 5.1%. The linear dependences are obtained based on the AChE-like activity of ZIF-8 for the detection of Cu2+, ST, and glucose in the ranges of 0.021-1.34 and 5.38-689.66 µM, 43.10-517.24 µM, and 0.0054-1.40 mM, respectively. The limit of detections (LODs) are calculated to be 20.00 nM, 9.25 µM, and 5.24 µM, respectively. Moreover, the sample spiked recoveries of Cu2+ in lake water, ST in milk, and glucose in strawberry samples were measured, and the results are in the range of 98.4-115.4% with the RSD (n = 3) lower than 3.3%. In addition, the method shows high selectivity in the real sample analysis.