Carotid flow as a surrogate of the left ventricular stroke volume.
Cheong, Issac; Otero Castro, Victoria; Sosa, Fernando Ariel; Tort Oribe, Bárbara; Merlo, Pablo Martín; Tamagnone, Francisco Marcelo.
Afiliação
  • Cheong I; Department of Critical Care Medicine, Sanatorio de los Arcos, Buenos Aires, Argentina. issac_cheong@hotmail.com.
  • Otero Castro V; Argentinian Critical Care Ultrasonography Association (ASARUC), Buenos Aires, Argentina. issac_cheong@hotmail.com.
  • Sosa FA; Department of Critical Care Medicine, Sanatorio de los Arcos, Buenos Aires, Argentina.
  • Tort Oribe B; Argentinian Critical Care Ultrasonography Association (ASARUC), Buenos Aires, Argentina.
  • Merlo PM; Department of Critical Care Medicine, Hospital Aleman, Buenos Aires, Argentina.
  • Tamagnone FM; Department of Critical Care Medicine, Hospital Aleman, Buenos Aires, Argentina.
J Clin Monit Comput ; 37(2): 661-667, 2023 04.
Article em En | MEDLINE | ID: mdl-36399216
Transthoracic echocardiography (TTE) is a fundamental tool for hemodynamic monitoring in critical patients. It allows evaluating the left ventricle's stroke volume based on the measurement of the velocity-time integral (VTI) of the left ventricle outflow tract (LVOT). However, in the intensive care unit obtaining adequate echocardiographic views may present a challenge. We propose to measure, as a surrogate of the stroke volume, the carotid flow with a novel technique. This is an observational, prospective, and simple blind study, conducted in the intensive care unit of Sanatorio de los Arcos and Hospital Aleman, in Buenos Aires, Argentina. We measured the carotid systodiastolic flow (CSD) VTI and the carotid systolic flow (CS) VTI at the level of the left supraclavicular fossa and we compared it with the LVOT VTI obtained by TTE. We evaluated 43 subjects. Spearman's correlation coefficient between LVOT VTI and CS VTI was 0.81 (95% CI 0.67-0.89) and between LVOT VTI and CSD VTI was 0.89 (95% CI 0.81-0.94). The Bland-Altman method analysis of the 5-chamber apical window LVOT VTI compared to the CSD VTI showed a bias of - 0.2 (95% CI - 0.82 to 0.43), with a concordance interval between - 4.2 (95% CI - 5.2 to - 3.1) and 3.8 cm (95% CI 2.7 to 4.9). The percentage error was 37.9%. Almost 100% of the values fell within the concordance limits, and no trend was observed in bias across the spectrum of mean variables. Although the CSD VTI could not be interchangeable with the LVOT VTI, it could be considered as its surrogate.