Your browser doesn't support javascript.
loading
Development of a high energy resolution and wide dose rate range portable gamma-ray spectrometer.
Wang, Yichao; Feng, Changqing; Zhao, Maoyuan; Shan, Chenyu; Liu, Feng; Lei, Qingxin; Zhou, Ziheng; Liu, Shubin.
Afiliação
  • Wang Y; State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei 230026, China; Department of Modern Physics, University of Science and Technology of China, Hefei 230026, China.
  • Feng C; State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei 230026, China; Department of Modern Physics, University of Science and Technology of China, Hefei 230026, China. Electronic address: fengcq@ustc.edu.cn.
  • Zhao M; State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei 230026, China; Department of Modern Physics, University of Science and Technology of China, Hefei 230026, China.
  • Shan C; China Nuclear Power Technology Research Institute Co.,Ltd., Shenzhen Guangdong 518031, China.
  • Liu F; China Nuclear Power Technology Research Institute Co.,Ltd., Shenzhen Guangdong 518031, China.
  • Lei Q; China Nuclear Power Technology Research Institute Co.,Ltd., Shenzhen Guangdong 518031, China.
  • Zhou Z; State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei 230026, China; Department of Modern Physics, University of Science and Technology of China, Hefei 230026, China.
  • Liu S; State Key Laboratory of Particle Detection and Electronics, University of Science and Technology of China, Hefei 230026, China; Department of Modern Physics, University of Science and Technology of China, Hefei 230026, China.
Appl Radiat Isot ; 192: 110572, 2023 Feb.
Article em En | MEDLINE | ID: mdl-36444786
ABSTRACT
In this paper, a portable gamma-ray spectrometer for real-time and in-situ gamma-ray detection applications is presented. By combining a quasi-hemispherical CdZnTe (CZT) semiconductor detector and a Geiger-Muller (GM) counter together, a wide dose rate range is achieved, ranging from 0.1 µSv/h to 100 mSv/h with a relative error of less than 10%. The GM counter is used to measure dose rate from 1 mSv/h to 100 mSv/h. With CZT, the spectrometer can provide a high energy resolution spectrum for nuclide identification and a high precision dose rate at low dose rates. The full width half maximum (FWHM) resolution is 2.2% at 662 keV below 70 µSv/h and is better than 3.3% at 3.8 mSv/h. The weight of the spectrometer is 3.2 kg for handheld and the runtime is up to 12 h without charging. For preliminary applications, the spectrometer was used to measure the gamma radiation around the Back-n white neutron beam line at China Spallation Neutron Source and around the steam generator in the nuclear power plant at Daya Bay Nuclear Power Station.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiometria / Nêutrons Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Radiometria / Nêutrons Idioma: En Ano de publicação: 2023 Tipo de documento: Article