Your browser doesn't support javascript.
loading
Different approaches for estimation of the expanded uncertainty of an analytical method developed for determining pharmaceutical active compounds in wastewater using solid-phase extraction and a liquid chromatography coupled with tandem mass spectrometry method.
Rodrigues, João A; Silva, Sofia; Cardoso, Vitor Vale; Benoliel, Maria João; Almeida, Cristina M M.
Afiliação
  • Rodrigues JA; Empresa Portuguesa das Águas Livres, S.A. - Direção de Laboratórios e de Controlo de Qualidade da Água, Av. de Berlim, 15, 1800-031 Lisboa, Portugal.
  • Silva S; Empresa Portuguesa das Águas Livres, S.A. - Direção de Laboratórios e de Controlo de Qualidade da Água, Av. de Berlim, 15, 1800-031 Lisboa, Portugal.
  • Cardoso VV; Empresa Portuguesa das Águas Livres, S.A. - Direção de Laboratórios e de Controlo de Qualidade da Água, Av. de Berlim, 15, 1800-031 Lisboa, Portugal.
  • Benoliel MJ; Empresa Portuguesa das Águas Livres, S.A. - Direção de Laboratórios e de Controlo de Qualidade da Água, Av. de Berlim, 15, 1800-031 Lisboa, Portugal.
  • Almeida CMM; iMed.UL (Institute for Medicines and Pharmaceutical Sciences, Portugal), Faculty of Pharmacy, University of Lisboa, Av. Prof. Gama Pinto, 2, 1649-003 Lisboa, Portugal. calmeida@ff.ulisboa.pt.
Anal Methods ; 15(1): 109-123, 2022 12 22.
Article em En | MEDLINE | ID: mdl-36484434
Although the evaluation of the uncertainty of an analytical method is a mandatory step in the method's validation, its applicability to the monitoring of trace compounds in complex samples is not simple, nor is it part of the routine of most laboratories, namely those dedicated to research. This manuscript focuses on the full validation of an analytical procedure for determining trace concentrations of twenty-four pharmaceutical active compounds (PhACs) in wastewaters using solid-phase extraction (SPE) and ultra-high performance liquid chromatography coupled with tandem mass spectrometry (UHPLC-MS/MS). The method optimization was performed on different wastewater matrices, namely influents and final effluents from two distinct wastewater treatment plants (WWTPs). Matrix effects and extraction efficiency (absolute recovery) of the developed method were determined. Validation was performed to obtain the method's linearity/working range, precision, trueness, method detection limits (MDLs) and method quantification limits (MQLs). The expanded uncertainty of the data obtained was estimated according to the requirements of international procedures dedicated to the expression of uncertainty. Different approaches for the estimation of uncertainty were applied. The validated method was used in the analysis of target PhACs in wastewater samples collected at two WWTPs. The obtained results facilitated the introduction of a validated method for routine measurement of PhACs in wastewater samples and allowed method accreditation by the competent national authority.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Espectrometria de Massas em Tandem Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Espectrometria de Massas em Tandem Idioma: En Ano de publicação: 2022 Tipo de documento: Article