Your browser doesn't support javascript.
loading
Sex Steroid Hormone Analysis in Human Tear Fluid Using a Liquid Chromatography-Mass Spectrometry Method.
Robciuc, Alexandra; Savolainen-Peltonen, Hanna; Haanpää, Mikko; Moilanen, Jukka A O; Mikkola, Tomi S.
Afiliação
  • Robciuc A; Obstetrics and Gynecology, Helsinki University Hospital, University of Helsinki, FIN-00029 HUS Helsinki, Finland.
  • Savolainen-Peltonen H; Helsinki Eye Lab, Ophthalmology Department, Helsinki University Hospital, University of Helsinki, FIN-00029 HUS Helsinki, Finland.
  • Haanpää M; Obstetrics and Gynecology, Helsinki University Hospital, University of Helsinki, FIN-00029 HUS Helsinki, Finland.
  • Moilanen JAO; HUSLAB, Helsinki University Hospital, FIN-00029 HUS Helsinki, Finland.
  • Mikkola TS; Helsinki Eye Lab, Ophthalmology Department, Helsinki University Hospital, University of Helsinki, FIN-00029 HUS Helsinki, Finland.
Int J Mol Sci ; 23(23)2022 Nov 28.
Article em En | MEDLINE | ID: mdl-36499192
ABSTRACT
The marked sexual dimorphism prevalent in inflammatory/autoimmune diseases is mostly due to sex hormone actions. One common eye disease that disproportionately affects women is dry eye. Thus, our aim was to optimise our highly sensitive liquid chromatography-tandem mass spectrometry method for steroid hormone quantification in tear fluid (TF). We used tears and matched serum samples from 10 heathy individuals. Estrone, estradiol testosterone, progesterone, androstenedione, and dehydroepiandrosterone, were quantified with an HPLC coupled with a Triple Quad 5500 MS. Estrone was measured in 80% of female and 20% of male TF samples (mean ± SD, 68.9 ± 62.2 pmol/L), whereas estradiol was undetectable in tears. Progesterone was identified in half of the female tear samples (2.91 ± 3.47 nmol/L) but in none of the male samples, whereas testosterone was quantifiable only in male tears (0.24 ± 0.1 nmol/L). TF hormone levels were, on average, from 1.4% to 55% of systemic values. Estrone, progesterone, and testosterone levels in tears correlated with the matching serum samples (r = 0.82, 0.79, and 0.85, respectively), but androstenedione and dehydroepiandrosterone showed no correlations. Our LC-MS/MS method could detect five out of the six steroid hormones studied in individual human TF samples and could therefore be used to analyse the role of sex steroids in eye diseases.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Progesterona / Estrona Limite: Female / Humans / Male Idioma: En Ano de publicação: 2022 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Progesterona / Estrona Limite: Female / Humans / Male Idioma: En Ano de publicação: 2022 Tipo de documento: Article