Your browser doesn't support javascript.
loading
Cascade-Gates Guarded Asymmetrical Nanochannel Membrane: An Interference-Free Device for Straightforward Detection of Trace Biomarker in Undiluted Serum.
Jian, Xiaoxia; Xu, Jing; Guo, Junli; Zhao, Junjian; Shen, Tian; Gao, Zhida; Song, Yan-Yan.
Afiliação
  • Jian X; Department of Chemistry, College of Science, Northeastern University, Shenyang, 110819, P. R. China.
  • Xu J; Department of Chemistry, College of Science, Northeastern University, Shenyang, 110819, P. R. China.
  • Guo J; Department of Chemistry, College of Science, Northeastern University, Shenyang, 110819, P. R. China.
  • Zhao J; Department of Chemistry, College of Science, Northeastern University, Shenyang, 110819, P. R. China.
  • Shen T; Department of Chemistry, College of Science, Northeastern University, Shenyang, 110819, P. R. China.
  • Gao Z; Department of Chemistry, College of Science, Northeastern University, Shenyang, 110819, P. R. China.
  • Song YY; Department of Chemistry, College of Science, Northeastern University, Shenyang, 110819, P. R. China.
Small ; 19(7): e2205995, 2023 02.
Article em En | MEDLINE | ID: mdl-36504175
ABSTRACT
Accurate detection of trace biomarkers in biological samples is a key task in diagnostic testing, but it remains challenging due to the high concentration of other physiologically relevant interferences. This work presents a new electrochemiluminescence (ECL) sensing device based on a bio-inspired nanochannel membrane (NM) guarded with two differential gates. The recognition event at the aptamer gate is followed by the permitting of stimulator transport toward the metal-organic framework (MOF) gate. Proof of concept application is evaluated using cytochrome C (Cytc) as the analyte, and glucose, a commonly existing nutriment as the stimulator. The oxidase-mimic plasmonic nanoparticles induce an effective release of ECL luminophore from the MOF gate. This cascade-gates guarded NM can effectively separate biological matrices from the detection cell. Consequently, the proposed system can achieve direct sensing of 1.0 nm Cytc in undiluted serum within the threshold concentrations of leukemia and lymphoma, making it attractive for point-of-care applications.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas / Nanopartículas Metálicas / Estruturas Metalorgânicas Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanopartículas / Nanopartículas Metálicas / Estruturas Metalorgânicas Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article