Your browser doesn't support javascript.
loading
One-step rapid colorimetric detection of K+ using silver nanoparticles modified by crown ether.
Sun, Yufeng; Wang, Shengwen; Wang, Fangfang; Zhang, Hao; Huang, Weiya; Wu, Aiguo; Zhang, Yujie.
Afiliação
  • Sun Y; Faculty of Materials, Metallurgical and Chemistry, Jiangxi University of Science and Technology, Ganzhou 341000, China. hweiya@126.com.
  • Wang S; Cixi Institute of Biomedical Engineering, International Cooperation Base of Biomedical Materials Technology and Application, CAS Key Laboratory of Magnetic Materials and Devices and Zhejiang Engineering Research Center for Biomedical Materials, Ningbo Institute of Materials Technology and Engineerin
  • Wang F; Advanced Energy Science and Technology Guangdong Laboratory, Huizhou 516000, China.
  • Zhang H; Cixi Institute of Biomedical Engineering, International Cooperation Base of Biomedical Materials Technology and Application, CAS Key Laboratory of Magnetic Materials and Devices and Zhejiang Engineering Research Center for Biomedical Materials, Ningbo Institute of Materials Technology and Engineerin
  • Huang W; Cixi Institute of Biomedical Engineering, International Cooperation Base of Biomedical Materials Technology and Application, CAS Key Laboratory of Magnetic Materials and Devices and Zhejiang Engineering Research Center for Biomedical Materials, Ningbo Institute of Materials Technology and Engineerin
  • Wu A; Cixi Institute of Biomedical Engineering, International Cooperation Base of Biomedical Materials Technology and Application, CAS Key Laboratory of Magnetic Materials and Devices and Zhejiang Engineering Research Center for Biomedical Materials, Ningbo Institute of Materials Technology and Engineerin
  • Zhang Y; Faculty of Materials, Metallurgical and Chemistry, Jiangxi University of Science and Technology, Ganzhou 341000, China. hweiya@126.com.
Analyst ; 148(2): 344-353, 2023 Jan 16.
Article em En | MEDLINE | ID: mdl-36533333
ABSTRACT
Urinary potassium is an important parameter in clinical health diagnosis. Rapid and convenient detection of potassium ions (K+) in urine is essential for personal healthcare and health management. Here, crown ether (4-aminodibenzo-18-crown-6, ADC) modified silver nanoparticles (ADC-Ag NPs) were successfully prepared for one-step rapid colorimetric detection of urinary potassium. The detection mechanism is as follows due to the matching sizes of the diameter of K+ and the cavity in crown ether 6, K+ is encapsulated between the cavities of two crown ethers, resulting in the clumping of ADC-Ag NPs and the color of the solution being altered. The colorimetric detection method has a fast response and is completed within 20 minutes. It also shows good selectivity and interference immunity. The lowest detectable concentration is 20 µM with the naked eye and 2.16 µM for UV-vis absorption spectroscopy. A good linear relationship (R2 = 0.9931) between the absorption intensity ratio and K+ concentration (0-100 µM) indicates that this colorimetric probe can be used to detect K+. The method was also applied for quantitative analysis of K+ in real urine samples with recovery between 116 and 120%.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Éteres de Coroa / Nanopartículas Metálicas Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Éteres de Coroa / Nanopartículas Metálicas Tipo de estudo: Diagnostic_studies Idioma: En Ano de publicação: 2023 Tipo de documento: Article