Your browser doesn't support javascript.
loading
A new DGT technique based on nano-sized Mg2Al layered double hydroxides with DTPA for sampling of eight anionic and cationic metals.
Wang, Zhen; Er, Qian; Zhang, Chuangchuang; Liu, Jiang; Liang, Xuefeng; Zhao, Yujie.
Afiliação
  • Wang Z; Ministry of Agriculture and Rural Affairs, Key Laboratory for Environmental Factors Control of Agro-Product Quality Safety, Tianjin, 300191, China.
  • Er Q; Ministry of Agriculture and Rural Affairs, Agro-Environmental Protection Institute, Tianjin, 300191, China.
  • Zhang C; Ministry of Agriculture and Rural Affairs, Key Laboratory for Environmental Factors Control of Agro-Product Quality Safety, Tianjin, 300191, China.
  • Liu J; Ministry of Agriculture and Rural Affairs, Agro-Environmental Protection Institute, Tianjin, 300191, China.
  • Liang X; Ministry of Agriculture and Rural Affairs, Key Laboratory for Environmental Factors Control of Agro-Product Quality Safety, Tianjin, 300191, China.
  • Zhao Y; Ministry of Agriculture and Rural Affairs, Agro-Environmental Protection Institute, Tianjin, 300191, China.
Environ Sci Pollut Res Int ; 30(13): 37679-37690, 2023 Mar.
Article em En | MEDLINE | ID: mdl-36572777
ABSTRACT
In this work, a new resin gel incorporated with layered double hydroxide nanoparticles modified with diethylenetriaminepentaacetic acid is developed for application in diffusive gradients in thin-film devices (abbreviated as LDHs DGT) to monitor eight anions and cations (such as Fe, Mn, Co, Ni, Cu, Cd, Pb, and As) in natural waters and soils. The accumulated anions and cations were quantitatively recovered by one-step elution using 0.5 mol·L-1 HNO3 with an optimized elution time of 30 min. The performance of the LDHs DGT was independent of solution pH (5-8) and ionic strengths (5-100 mmol·L-1). The capacities of the LDHs DGT for Mn(II), Fe(II), Co(II), Ni(II), Cu(II), As(V), Cd(II), and Pb(II) individually are determined to be 202.9, 363.6, 246.9, 88.8, 99.5, 75.3, 159.8, and 671.7 µg·cm-2. During the field deployments in a nature river, LDHs DGT measured concentrations of cations and anions were almost like those measured by the traditional sampling method (except Fe(II), Cd(II), and Co(II)). In addition, bioavailable Cd measured by LDHs DGT correlated well with Cd in rice grains (R2 = 0.55), indicating that LDHs DGT is a reliable tool for assessing the risk of Cd.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Cádmio Idioma: En Ano de publicação: 2023 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água / Cádmio Idioma: En Ano de publicação: 2023 Tipo de documento: Article